TIDT367 December   2023

 

  1.   1
  2.   Description
  3.   Features
  4.   Applications
  5. 1Test Prerequisites
    1. 1.1 Voltage and Current Requirements
    2. 1.2 Required Equipment
    3. 1.3 Test Setup
      1. 1.3.1 Hardware Setup
      2. 1.3.2 Software Setup
    4. 1.4 Running the Code for Different Labs
      1. 1.4.1 Lab 1. Primary to Secondary Power Flow, Open Loop Check PWM Driver
      2. 1.4.2 Lab 2. Primary to Secondary Power Flow, Open Loop CheckPWM Driver and ADC With Protection
      3. 1.4.3 Lab 3. Primary to Secondary Power Flow, Closed Voltage Loop Check
      4. 1.4.4 Lab 4. Primary to Secondary Power Flow, Closed Current Loop Check
      5. 1.4.5 Lab 6. Secondary to Primary Power Flow, Open Loop Check PWM Driver
      6. 1.4.6 Lab 7. Secondary to Primary Power Flow, Open Loop Check PWM Driver and ADC With Protection
      7. 1.4.7 Lab 8. Secondary to Primary Power Flow, Closed Voltage Loop Check
  6. 2Testing and Results
    1. 2.1 Efficiency Graphs
    2. 2.2 Efficiency Data
    3. 2.3 Thermal Images
    4. 2.4 Bode Plots
  7. 3Waveforms
    1. 3.1 Switching
    2. 3.2 Load Transients
    3. 3.3 Start-Up Sequence
    4. 3.4 Dynamic Response
    5. 3.5 Mode Transition

Load Transients

Load transient response is shown in the following figures.

GUID-20231108-SS0I-B9MJ-DPN4-PQQDXT2GJNF9-low.png
CH1: Primary Tank Current, CH2: Output Voltage
Figure 3-5 400 VIN, 48 VOUT,
50% Load to 5% Load Transient
GUID-20231108-SS0I-TTJZ-M3BS-BMV0RM3STVF0-low.png
CH1: Primary Tank Current, CH2: Output Voltage
Figure 3-6 400 VIN, 48 VOUT,
5% Load to 50% Load Transient