Figure 3-22 through Figure 3-21 show the load transient waveforms at various input voltages with the output undergoing a 20A-to-50A load step, with the device configured in FPWM mode.

GUID-20240213-SS0I-NFN9-ZSXW-K6MBT0BHKDQQ-low.pngFigure 3-19 Load Transient Response, 24V Input, 20A-to-50A Load Step, FPWM Mode
GUID-20240213-SS0I-LZXZ-ZC5M-XKWQ37FZ8WKC-low.pngFigure 3-21 Load Transient Response, 60V Input, 20A-to-50A Load Step, FPWM Mode