TIDT384 February   2024

 

  1.   1
  2.   Description
  3.   Features
  4.   Applications
  5. 1Test Prerequisites
    1. 1.1 Voltage and Current Requirements
    2. 1.2 Required Equipment
    3. 1.3 Considerations
  6. 2Testing and Results
    1. 2.1 Efficiency, Power Loss, and Load Regulation Graphs
    2. 2.2 Thermal Images
    3. 2.3 Dimensions
  7. 3Waveforms
    1. 3.1 Switching
    2. 3.2 Output Voltage Ripple
    3. 3.3 Load Transient Response
    4. 3.4 Start-Up

Considerations

Unless stated otherwise, the tests performed in this test report are taken at the nominal 48V input voltage and 30A load current and the device is configured to PFM mode.