Output Voltage Ripple

Output voltage ripple is shown in Figure 3-10 through Figure 3-15. The test condition is room temperature.

PMP41078 Output Voltage Ripple at 200Vin,
                            13.5Vout, 20A LoadFigure 3-10 Output Voltage Ripple at 200Vin, 13.5Vout, 20A Load
PMP41078 Output Voltage Ripple at 320Vin,
                            13.5Vout, 20A LoadFigure 3-12 Output Voltage Ripple at 320Vin, 13.5Vout, 20A Load
PMP41078 Output Voltage Ripple at 400Vin,
                            13.5Vout, 20A LoadFigure 3-14 Output Voltage Ripple at 400Vin, 13.5Vout, 20A Load
PMP41078 Output Voltage Ripple at 200Vin,
                            13.5Vout, 120A LoadFigure 3-11 Output Voltage Ripple at 200Vin, 13.5Vout, 120A Load
PMP41078 Output Voltage Ripple at 320Vin,
                            13.5Vout, 120A LoadFigure 3-13 Output Voltage Ripple at 320Vin, 13.5Vout, 120A Load
PMP41078 Output Voltage Ripple at 400Vin,
                            13.5Vout, 120A LoadFigure 3-15 Output Voltage Ripple at 400Vin, 13.5Vout, 120A Load