TIDT407 October   2024

 

  1.   1
  2.   Description
  3.   Features
  4.   Applications
  5. 1Test Prerequisites
    1. 1.1 Voltage and Current Requirements
    2. 1.2 Required Equipment
    3. 1.3 Considerations
    4. 1.4 Dimensions
    5. 1.5 Test Setup
  6. 2Testing and Results
    1. 2.1 Efficiency Graphs
    2. 2.2 Efficiency Data
    3. 2.3 Thermal Images
  7. 3Waveforms
    1. 3.1 Charge Mode Start-Up Waveform
    2. 3.2 OTG Mode Start-Up Waveform
    3. 3.3 Voltage Transition at OTG Mode
    4. 3.4 Ripple and Noise at OTG Mode
    5. 3.5 Load Transients at OTG Mode
    6. 3.6 Switching Waveform
    7. 3.7 Overcurrent Protection at OTG Mode
    8. 3.8 Short-Circuit Protection
  8.   Trademarks

Voltage and Current Requirements

Table 1-1 Voltage and Current Requirements
PARAMETERSPECIFICATIONS
Sink input voltage range5VDC to 48 VDC
Source output voltage range5V, 9V, 15V, 20V, 36V, 48V
Battery cell configuration10 to 12 Cells
Maximum input current5A
Maximum power240W
Switching frequency300kHz
Efficiency97.6% at full load