TIDT423 December   2024

 

  1.   1
  2.   Description
  3.   Features
  4.   Applications
  5. 1Test Prerequisites
    1. 1.1 Voltage and Current Requirements
    2. 1.2 Required Equipment
    3. 1.3 Dimensions
  6. 2Testing and Results
    1. 2.1 Efficiency Graphs
    2. 2.2 Voltage Regulation
    3. 2.3 Efficiency Data
    4. 2.4 Thermal Images
    5. 2.5 EMI
  7. 3Waveforms
    1. 3.1 Start-up and Shut Down Waveform
    2. 3.2 Switching
      1. 3.2.1 Voltage Stress
    3. 3.3 VCC Self Bias
    4. 3.4 Output Voltage Ripple
    5. 3.5 Load Dynamic Response
    6. 3.6 Peak Power
    7. 3.7 Short-Circuit Protection
    8. 3.8 Output Over Voltage Protection

Required Equipment

  • AC Source: Chroma Model 61601
  • Digital Power Meter: Yokogawa WT310
  • Power-Z P240 Bidirectional Multi-protocol Power Supply
  • DC source: GWinstek, GPS-3303C
  • Bidirectional Power Source: IT6010C-80-300
  • Electronic load: Chroma, 6314A
  • Oscilloscope: Tektronix, DPO 3054
  • Infrared Thermal Camera: Fluke, TiS55
  • Ture-RMS-Multimeter: Fluke, 287C