TIDUEM7A April 2019 – February 2021
NUMBER OF ENABLED CHANNELS | CURRENT-DETECTION MODE CURRENT | AVERAGE CURRENT ESTIMATE AT tCD_mode_period=10 | AVERAGE CURRENT ESTIMATE AT tCD_mode_period=64 |
---|---|---|---|
2 (ch 1 and 2) | 626.822 µA | 7.421 µA | 2.385 µA |
2 (ch 0 and 1) | 565.645 µA | 6.837 µA | 2.293 µA |
1 (ch 2) | 386.59 µA | 5.128 µA | 2.026 µA |
1 (ch 1) | 397.716 µA | 5.234 µA | 2.043 µA |
1 (ch 0) | 391.505 µA | 5.175 µA | 2.034 µA |
When Channel 0 and 1 are enabled, the current consumption is smaller than when channel 1 and 2 are enabled because enabling only channel 0 and 1 allows the shared circuitry between channels 2 and 3 to be turned off. In addition, if current detection is only performed on one channel instead of the two channels used in this design, the average current consumption can be reduced.
STANDBY MODE | CURRENT CONSUMPTION | DURATION ESTIMATE |
---|---|---|
Average from standby mode trials on 3 boards | 1.452 µA | 9904.548 ms |
Average from current-detection mode trials on 3 boards | 636.155 µA | 95.453 ms |
Total average current consumption | 7.510 µA | 10000 ms |
STANDBY MODE | CURRENT CONSUMPTION | DURATION ESTIMATE |
---|---|---|
Average from standby mode trials on 3 boards | 1.452 µA | 63904.548 ms |
Average from current-detection mode trials on 3 boards | 636.155 µA | 95.453 ms |
Total average current consumption | 2.399 µA | 64000 ms |
The minimum triggering current for the shunt and CT channels was found to be 0.6 A and 1.2 A when testing was performed on one of these boards.