TIDUEM8B March 2019 – February 2021
FEATURES | DESCRIPTION |
---|---|
Number of phases | 1 (split-phase with two voltages measured), 1 (split-phase with one voltage measured), 2 phase |
Electricity meter accuracy class | Class 0.1 |
Current sensor | Current transformer |
Tested current range | 0.05–100 A |
Tested voltage range | 15 V–240 V |
ADS131M04 CLKIN frequency | 8,192,000 Hz |
ADS131M04 Delta-sigma modulation clock frequency | 4,096,000 Hz (= CLKIN / 2) |
SPI Clock | 8,192,000 Hz |
Oversampling ratio (OSR) | 512 |
Digital filter output sample rate | 8,000 samples per second |
Phase compensation implementation | Software |
Phase compensation resolution | 0.0088° at 50 Hz or 0.0105° at 60 Hz |
Selected CPU clock frequency | 48 MHz |
MCU External SVS voltage | 2.0–2.1 V |
System nominal frequency | 50 or 60 Hz |
Measured parameters |
|
Update rate for measured parameters | Approximately equal to 1 second |
Communication options |
|
Utilized LEDs | Total active energy and total reactive energy |