TIDUEW7 May 2020
This section contains information about the initial set-up of the TIDA-050043 board, power-up options and user interfaces. Figure 23 shows the top side of the fully assembled PCB with labels to help locate connectors or switches on the boards.
Figure 24 shows the bottom side of the fully assembled PCB with labels.
The following is a list of steps that must be followed to set up the hardware of the system.
NOTE
The voltage of the coin-cell battery (3.0 V nominal) must be above 2.4 V for the supervisor to allow system power-on. If the coin-cell battery voltage is too low, it must be replaced with a fresh battery to continue testing.
NOTE
Refer to Section 3.1.2 for the procedure to debug TIDA-050043 through Terminal window
NOTE
Power supplies other than the SMI24-5-V-P6 may be substituted if the DC output voltage, current rating, polarity, and barrel jack size (inside diameter and outside diameter) are equivalent. Power supplies with DC voltage greater than 5.25V are not acceptable because of the over voltage protection circuit on the board which is intended to prevent damage to the ICs.
NOTE
It is always recommended to power-down the system by switching SW1 to the OFF position before unplugging the DC adapter power supply.