TIDUEZ8C december 2022 – june 2023
The conditioning can be done through the calculation tool Isolated Amplifier Voltage Sensing Excel Calculator. The tool offers a detailed worst-case error analysis across temperature considering gain error and drift, and offset error and drift, and non-linearity drift. Note that the error analysis is output referenced.
The main sources of error in the signal chain are the resistor tolerances, gain and offset errors off the AMC3330, and gain and offset errors in the differential-to-single-ended conversion circuitry. There is another TIDA-010232 specific worst-case error calculation excel sheet available on the reference design page. This sheet assumes the absolute worst-case for each parameter in the signal chain and finds the combination of these which results in the worst accuracy. As shown in Section 3.5, the actual measured accuracy is in most cases better than the worst-case assumption.
If higher accuracy is desired, precision op amps can be used for the differential-to-single-ended conversion, such as the TLV6001 pin-to-pin compatible OPA320 (Voffset 0.15 mV). To improve accuracy even further, the differential-to single-ended conversion can be removed by choosing a dedicated differential input ADC instead of the internal ADC of the C2000 microcontroller.