TIDUF61 May 2024
PARAMETER | CONDITIONS | TYP | UNIT |
---|---|---|---|
Input voltage | DC battery voltage | 12 | V |
Interlock voltage | LDO voltage output for loop | 5 | V |
Interlock loop current | Constant current generated by HVIL (configurable) | 10 | mA |
Load Resistance | Expected load resistance of four high-voltage connectors | 200 | Ω |
Short to ground current | Expected current for short to ground | 15–45 | mA |
Short to battery current | Expected current for short to battery | 15–25 | mA |
Disable current | Expected current when in DISABLE mode | < 1 | mA |