TIDUF98 October 2024
FEATURES | DESCRIPTION |
---|---|
Number of phases | 1 |
Electricity meter accuracy class | Class 0.5S |
Current sensor | Shunt |
Tested current range | 0.025–100A |
Tested voltage range | 10 - 270V |
ADS131M03 CLKIN frequency | 8,192,000Hz |
ADS131M03 delta-sigma modulation clock frequency | 4,096,000Hz (= CLKIN / 2) |
SPI Clock | 8,000,000Hz |
Oversampling ratio (OSR) | 512 |
Digital filter output sample rate | 8,000 samples per second |
Phase compensation implementation | Software |
Phase compensation resolution | 0.0088° at 50Hz or 0.0105° at 60Hz |
Selected CPU clock frequency | 32MHz |
System nominal frequency | 50 or 60Hz |
Measured parameters |
|
Update rate for measured parameters | Approximately equal to 1 second |
Communication options |
|
Utilized LEDs | Active energy and reactive energy |
Board power supply | External power: 3V3 and GND |