TIDUF98 October   2024

 

  1.   1
  2.   Description
  3.   Resources
  4.   Features
  5.   Applications
  6.   6
  7. 1System Description
    1. 1.1 End Equipment
      1. 1.1.1 Electricity Meter
    2. 1.2 Key System Specifications
  8. 2System Overview
    1. 2.1 Block Diagram
    2. 2.2 Highlighted Products
      1. 2.2.1 ADS131M03
      2. 2.2.2 MSPM0L2228
      3. 2.2.3 THVD1400
      4. 2.2.4 ISO6731
      5. 2.2.5 DRV5032
    3. 2.3 Design Considerations
      1. 2.3.1 Design Hardware Implementation
        1. 2.3.1.1 Analog Inputs
          1. 2.3.1.1.1 Voltage Measurement Analog Front End
          2. 2.3.1.1.2 Current Measurement Analog Front End
      2. 2.3.2 Energy Metrology Software
        1. 2.3.2.1 Software Architecture
        2. 2.3.2.2 Setup
          1. 2.3.2.2.1 Clocking Scheme
          2. 2.3.2.2.2 SPI
          3. 2.3.2.2.3 UART Setup for GUI Communication
          4. 2.3.2.2.4 Real-Time Clock
          5. 2.3.2.2.5 LCD Controller
          6. 2.3.2.2.6 Direct Memory Access
    4. 2.4 Hardware, Software, Testing Requirements, and Test Results
      1. 2.4.1 Required Hardware and Software
        1. 2.4.1.1 Cautions and Warnings
        2. 2.4.1.2 Hardware
          1. 2.4.1.2.1 Connections to the Test Setup
          2. 2.4.1.2.2 Power Supply Options and Jumper Settings
        3. 2.4.1.3 Calibration
      2. 2.4.2 Testing and Results
        1. 2.4.2.1 Test Setup
          1. 2.4.2.1.1 Viewing Metrology Readings and Calibration
            1. 2.4.2.1.1.1 Viewing Results From LCD
            2. 2.4.2.1.1.2 Viewing Results From PC GUI
        2. 2.4.2.2 Electricity Meter Metrology Accuracy Testing
        3. 2.4.2.3 Electricity Meter Metrology Accuracy Results
  9. 3Design Files
    1. 3.1 Schematics
    2. 3.2 Bill of Materials
    3. 3.3 PCB Layout Recommendations
      1. 3.3.1 Layout Prints
    4. 3.4 Altium Project
    5. 3.5 Gerber Files
    6. 3.6 Assembly Drawings
  10. 4Related Documentation
    1. 4.1 Trademarks
  11. 5About the Authors

Key System Specifications

Table 1-1 Key System Specifications
FEATURES DESCRIPTION
Number of phases 1
Electricity meter accuracy class Class 0.5S
Current sensor Shunt
Tested current range 0.025–100A
Tested voltage range 10 - 270V
ADS131M03 CLKIN frequency 8,192,000Hz
ADS131M03 delta-sigma modulation clock frequency 4,096,000Hz (= CLKIN / 2)
SPI Clock 8,000,000Hz
Oversampling ratio (OSR) 512
Digital filter output sample rate 8,000 samples per second
Phase compensation implementation Software
Phase compensation resolution 0.0088° at 50Hz or 0.0105° at 60Hz
Selected CPU clock frequency 32MHz
System nominal frequency 50 or 60Hz
Measured parameters
  • Active, reactive, apparent power and energy
  • Root mean square (RMS) line current, neutral current, and voltage
  • Power factor
  • Line frequency
Update rate for measured parameters Approximately equal to 1 second
Communication options
  • LCD
  • PC GUI through 5kVRMS isolated RS-485
Utilized LEDs Active energy and reactive energy
Board power supply External power: 3V3 and GND