The UCC25640x is the latest family of LLC controllers from Texas Instruments. The UCC25640x has improved features and optimized performance compared to the previous generation devices UCC25630x. This application note briefly discusses each feature of the controller using block diagrams and typical waveforms. Finally, it goes through power up procedure and debugging tips for each pin of the controller.
All trademarks are the property of their respective owners.
UCC256402 | UCC256402A | UCC256403 | UCC256403A | UCC256404 | UCC256404A | UCC256404B | |
---|---|---|---|---|---|---|---|
Key Application | Lighting/Industrial | Lighting/Industrial | TV OLED Screen/Telecom/Industrial | TV OLED Screen/Telecom/Industrial | TV - WLLC | TV - WLLC | TV - WLLC |
Burst Packet Size | 16 | 16 | 40 | 16 | 40 | 16 | 40 |
Burst Soft On/Off | No | No | Yes | No | Yes | No | Yes |
HV Startup | Yes | Yes | No | No | Yes | Yes | Yes |
Auxiliary Supply Required | No | No | Yes | Yes | No | No | No |
X-Cap Discharge (XCD) | No | No | No | No | Yes | Yes | Yes |
BLK/DC Start (1) | 3 V/340 V | 3 V/340 V | 3 V/340 V | 3 V/340 V | 1 V/113 V | 1 V/113 V | 1 V/113 V |
BLK/DC Stop (1) | 2.2 V/249 V | 2.2 V/249 V | 2.2 V/249 V | 2.2 V/249 V | 0.9 V/102 V | 0.9 V/102 V | 0.9 V/102 V |
BLK/DC OVP (1) | NA | 4 V/453 V | NA | NA | NA | NA | NA |
BW OVP Mode | Restart | Restart | Restart | Latch | Restart | Latch | Restart |
Other Fault Mode | Restart | Restart | Restart | Restart | Restart | Restart | Restart |
PFC Off in Standby Mode | No | No | No | No | Yes | Yes | Yes |
VCC startup voltage that will initiate startup process | 26 V | 26 V | 10.9 V | 10.9 V | 26 V | 26 V | 26 V |
The UCC256404B maximum XCD test current is lower (1.3mA) compared to the maximum XCD test currents of the 404 and 404A (1.7mA). This difference helps to reduce stand-by power loss when using the UCC256404B during very-light-load to no-load conditions.