SLVSFR1
August 2020
TPS25980
PRODUCTION DATA
1
Features
2
Applications
3
Description
4
Revision History
5
Device Comparison Table
6
Pin Configuration and Functions
7
7
Specifications
7.1
Absolute Maximum Ratings
7.2
ESD Ratings
7.3
Recommended Operating Conditions
7.4
Thermal Information
7.5
Electrical Characteristics
7.6
Timing Requirements
7.7
Switching Characteristics
7.8
Typical Characteristics
8
Detailed Description
8.1
Overview
8.2
Functional Block Diagram
8.3
Feature Description
8.3.1
Undervoltage Protection (UVLO and UVP)
8.3.2
Overvoltage Protection (OVP)
8.3.3
Inrush Current, Overcurrent, and Short-Circuit Protection
8.3.3.1
Slew Rate and Inrush Current Control (dVdt)
8.3.3.2
Circuit Breaker
8.3.3.3
Short-Circuit Protection
8.3.4
Overtemperature Protection (OTP)
8.3.5
Analog Load Current Monitor (IMON)
8.3.6
Power Good (PG)
8.3.7
Load Detect/Handshake (LDSTRT)
8.4
Fault Response
8.5
Device Functional Modes
9
Application and Implementation
9.1
Application Information
9.2
Typical Application: Patient Monitoring System in Medical Applications
9.2.1
Design Requirements
9.2.2
Detailed Design Procedure
9.2.2.1
Device Selection
9.2.2.2
Setting the Current Limit Threshold: RILIM Selection
9.2.2.3
Setting the Undervoltage Lockout Set Point
9.2.2.4
Choosing the Current Monitoring Resistor: RIMON
9.2.2.5
Setting the Output Voltage Ramp Time (TdVdt)
9.2.2.5.1
Case 1: Start-Up Without Load: Only Output Capacitance COUT Draws Current
9.2.2.5.2
Case 2: Start-Up With Load: Output Capacitance COUT and Load Draw Current
9.2.2.6
Setting the Load Handshake (LDSTRT) Delay
9.2.2.7
Setting the Transient Overcurrent Blanking Interval (tITIMER)
9.2.2.8
Setting the Auto-Retry Delay and Number of Retries
9.2.3
Application Curves
9.3
System Examples
9.3.1
Optical Module Power Rail Path Protection
9.3.1.1
Design Requirements
9.3.1.2
Device Selection
9.3.1.3
External Component Settings
9.3.1.4
Voltage Drop
9.3.1.5
Application Curves
9.3.2
Input Protection for 12-V Rail Applications: PCIe Cards, Storage Interfaces and DC Fans
10
Power Supply Recommendations
10.1
Transient Protection
10.2
Output Short-Circuit Measurements
11
Layout
11.1
Layout Guidelines
11.2
Layout Example
12
Device and Documentation Support
12.1
Documentation Support
12.1.1
Related Documentation
12.1.1.1
Related Links
12.2
Receiving Notification of Documentation Updates
12.3
Support Resources
12.4
Trademarks
12.5
Electrostatic Discharge Caution
12.6
Glossary
13
Mechanical, Packaging, and Orderable Information
Package Options
Mechanical Data (Package|Pins)
RGE|24
MPQF124G
Thermal pad, mechanical data (Package|Pins)
RGE|24
QFND572A
Orderable Information
slvsfr1_oa
slvsfr1_pm
1
Features
Wide input voltage range: 2.7 V to 24 V
30-V Absolute maximum
Low On-Resistance: R
ON
= 3-mΩ typical
Circuit Breaker Response
Adjustable current limit threshold
Range: 2 A to 8 A
Accuracy: ± 8% (typical for I
LIM
> 5 A)
Adjustable over-current blanking timer
Handles load transients without tripping
Accurate current monitor output
± 3% (typical at 25 °C for I
OUT
> 3 A)
User configurable fault response
Latch-off or auto-retry
Number of retries (Finite or indefinite)
Delay between retries
Robust short-circuit protection
Fast-trip response time < 400-ns typical
Tested against 1 million power-into-short events
Immune to line transients - no nuisance tripping
Adjustable output slew rate (dVdt) control
Adjustable undervoltage lockout
Overvoltage lockout (Fixed 3.7-V, 7.6-V, 16.9-V and no-OVLO options)
Integrated overtemperature protection
Power good indication
Adjustable load detect and handshake timer
UL 2367 Recognition
File no. E339631
R
ILIM
≥ 182 Ω
IEC 62368 CB Certification
Small footprint: 4-mm × 4-mm QFN package