Protecting Delta-Sigma ADC: Input Protection Circuit Operation
00:11:36
|
11 APR 2022
This video explains how TVS diodes and current limiting resistors can be used to protect a Delta-Sigma RTD measurement circuit from a continuous 24V DC fault. The type and ratings of the TVS diode are covered.
Resources
download Presentation-
arrow-right Download and install TINA-TI, the preferred simulator used exclusively with TI Precision Labs. -
arrow-right Download and install the Analog Engineer's Calculator. -
arrow-right Download the Analog Engineer's Pocket Reference e-book. -
arrow-right Search TI precision ADCs, and find reference designs and other technical resources: www.ti.com/precisionadc.
This video is part of a series
-
Precision labs series: Analog-to-digital converters (ADCs)
video-playlist (94 videos)