SBASAI7 March   2023 ADC34RF52

PRODUCTION DATA  

  1. Features
  2. Applications
  3. Description
  4. Revision History
  5. Pin Configuration and Functions
  6. Specifications
    1. 6.1  Absolute Maximum Ratings
    2. 6.2  ESD Ratings
    3. 6.3  Recommended Operating Conditions
    4. 6.4  Thermal Information
    5. 6.5  Electrical Characteristics - Power Consumption
    6. 6.6  Electrical Characteristics - DC Specifications
    7. 6.7  Electrical Characteristics - AC Specifications (Dither DISABLED)
    8. 6.8  Electrical Characteristics - AC Specifications (Dither ENABLED)
    9. 6.9  Timing Requirements
    10. 6.10 Typical Characteristics
  7. Detailed Description
    1. 7.1 Overview
    2. 7.2 Functional Block Diagram
    3. 7.3 Feature Description
      1. 7.3.1 Analog Inputs
        1. 7.3.1.1 Input Bandwidth and Full-Scale
        2. 7.3.1.2 Input Imbalance
        3. 7.3.1.3 Overrange Indication
        4. 7.3.1.4 Analog out-of-band dither
      2. 7.3.2 Sampling Clock Input
      3. 7.3.3 SYSREF
        1. 7.3.3.1 SYSREF Capture Detection
      4. 7.3.4 ADC Foreground Calibration
        1. 7.3.4.1 Calibration Control
        2. 7.3.4.2 ADC Switch
        3. 7.3.4.3 Calibration Configuration
      5. 7.3.5 Decimation Filter
        1. 7.3.5.1 Decimation Filter Response
        2. 7.3.5.2 Decimation Filter Configuration
        3. 7.3.5.3 20-bit Output Mode
        4. 7.3.5.4 Numerically Controlled Oscillator (NCO)
        5. 7.3.5.5 NCO Frequency programming using the SPI interface
        6. 7.3.5.6 Fast Frequency Hopping
          1. 7.3.5.6.1 Fast frequency hopping using the GPIO1/2 pins
          2. 7.3.5.6.2 Fast frequency hopping using GPIO1/2, SEN and SDATA pins
          3. 7.3.5.6.3 Fast frequency hopping using the fast SPI
      6. 7.3.6 JESD204B Interface
        1. 7.3.6.1 JESD204B Initial Lane Alignment (ILA)
          1. 7.3.6.1.1 SYNC Signal
        2. 7.3.6.2 JESD204B Frame Assembly
          1. 7.3.6.2.1 JESD204B Frame Assembly in Bypass Mode
          2. 7.3.6.2.2 JESD204B Frame Assembly with Real Decimation - Single Band
          3. 7.3.6.2.3 JESD204B Frame Assembly with Decimation - Single Band
          4. 7.3.6.2.4 JESD204B Frame Assembly with Decimation - Dual Band
        3. 7.3.6.3 SERDES Output MUX
      7. 7.3.7 Test Pattern
        1. 7.3.7.1 Transport Layer
        2. 7.3.7.2 Link Layer
        3. 7.3.7.3 Internal Capture Memory Buffer
    4. 7.4 Device Functional Modes
      1. 7.4.1 Bypass Mode
      2. 7.4.2 Digital Averaging
    5. 7.5 Programming
      1. 7.5.1 GPIO Pin Control
      2. 7.5.2 Configuration using the SPI interface
        1. 7.5.2.1 Register Write
        2. 7.5.2.2 Register Read
    6. 7.6 Register Maps
      1. 7.6.1 Detailed Register Description
  8. Application Information Disclaimer
    1. 8.1 Application Information
    2. 8.2 Typical Application
      1. 8.2.1 Wideband RF Sampling Receiver
      2. 8.2.2 Design Requirements
        1. 8.2.2.1 Input Signal Path
        2. 8.2.2.2 Clocking
      3. 8.2.3 Detailed Design Procedure
        1. 8.2.3.1 Sampling Clock
      4. 8.2.4 Application Curves
    3. 8.3 Initialization Set Up
      1. 8.3.1 Initial Device Configuration After Power-Up
        1. 8.3.1.1  STEP 1: RESET
        2. 8.3.1.2  STEP 2: Device Configuration
        3. 8.3.1.3  STEP 3: JESD Interface Configuration (1)
        4. 8.3.1.4  STEP 4: SYSREF Synchronization
        5. 8.3.1.5  STEP 5: JESD Interface Configuration (2)
        6. 8.3.1.6  STEP 6: Analog Trim Settings
        7. 8.3.1.7  STEP 7: Calibration Configuration
        8. 8.3.1.8  STEP 8: SYSREF Synchronization
        9. 8.3.1.9  STEP 9: Run Power up Calibration
        10. 8.3.1.10 Step 10: JESD Interface Synchronization
    4. 8.4 Power Supply Recommendations
    5. 8.5 Layout
      1. 8.5.1 Layout Guidelines
      2. 8.5.2 Layout Example
  9. Device and Documentation Support
    1. 9.1 Receiving Notification of Documentation Updates
    2. 9.2 Support Resources
    3. 9.3 Trademarks
    4. 9.4 Electrostatic Discharge Caution
    5. 9.5 Glossary
  10. 10Mechanical, Packaging, and Orderable Information

Package Options

Mechanical Data (Package|Pins)
Thermal pad, mechanical data (Package|Pins)
Orderable Information

Input Bandwidth and Full-Scale

The input bandwidth (-3 dB) and input fullscale are dependent on what input termination and averaging mode are chosen as shown in the summary in Table 7-1. With averaging enabled the -3 dB bandwidth reduces to ~ 1.5 GHz and 100 Ω differential termination; the bandwidth can be increased by changing the input termination to
50 Ω differential.

Table 7-1 Digital averaging vs full power input bandwidth (–3 dB)
# of ADCs averagedInput Bandwidth (-3 dB)Reset SwitchSelected differential input terminationInput Full-scale
1 (Default)1.6 GHz1100 Ω+ 1 dBm
21.5 GHz1+ 1.8 dBm
11.5 GHz0+ 0.5 dBm
20.8 GHz0

There is an internal RESET switch which resets the sampling capacitor to VCM in between samples when enabled. The full power input bandwidth plots with input RESET switch disabled (RSW0) and enabled (RSW1) are shown in #FIG_EG1_NHV_FNB.

Figure 7-2 Full power input bandwidth (100 Ω)

The RESET switch is enabled by default and can be disabled with the following register writes:

Table 7-2 Register Write Example for Configuring the RESET Switch
ADDRDATADESCRIPTION
0x050x40Select ANALOG page
0x6D0xC0Disable RESET Switch (to enable: 0x00)
0x6E0x08Disable RESET Switch (to enable: 0x00)