SBAS661C February   2015  – May 2021 ADS1262 , ADS1263

PRODUCTION DATA  

  1. Features
  2. Applications
  3. Description
  4. Revision History
  5. Device Comparison
  6. Pin Configuration and Functions
  7. Specifications
    1. 7.1 Absolute Maximum Ratings
    2. 7.2 ESD Ratings
    3. 7.3 Recommended Operating Conditions
    4. 7.4 Thermal Information
    5. 7.5 Electrical Characteristics
    6. 7.6 Timing Requirements: Serial Interface
    7. 7.7 Switching Characteristics: Serial Interface
    8. 7.8 Timing Diagrams
    9. 7.9 Typical Characteristics
  8. Parameter Measurement Information
    1. 8.1 Offset Temperature Drift Measurement
    2. 8.2 Gain Temperature Drift Measurement
    3. 8.3 Common-Mode Rejection Ratio Measurement
    4. 8.4 Power-Supply Rejection Ratio Measurement
    5. 8.5 Crosstalk Measurement (ADS1263)
    6. 8.6 Reference-Voltage Temperature-Drift Measurement
    7. 8.7 Reference-Voltage Thermal-Hysteresis Measurement
    8. 8.8 Noise Performance
  9. Detailed Description
    1. 9.1 Overview
    2. 9.2 Functional Block Diagram
    3. 9.3 Feature Description
      1. 9.3.1  Multifunction Analog Inputs
      2. 9.3.2  Analog Input Description
        1. 9.3.2.1 ESD Diode
        2. 9.3.2.2 Input Multiplexer
      3. 9.3.3  Sensor Bias
      4. 9.3.4  Temperature Sensor
      5. 9.3.5  Power-Supply Monitor
      6. 9.3.6  PGA
      7. 9.3.7  PGA Voltage Overrange Monitors
        1. 9.3.7.1 PGA Differential Output Monitor
        2. 9.3.7.2 PGA Absolute Output-Voltage Monitor
      8. 9.3.8  ADC Reference Voltage
        1. 9.3.8.1 Internal Reference
        2. 9.3.8.2 External Reference
        3. 9.3.8.3 Power-Supply Reference
        4. 9.3.8.4 Low-Reference Monitor
      9. 9.3.9  ADC1 Modulator
      10. 9.3.10 Digital Filter
        1. 9.3.10.1 Sinc Filter Mode
          1. 9.3.10.1.1 Sinc Filter Frequency Response
        2. 9.3.10.2 FIR Filter
        3. 9.3.10.3 50-Hz and 60-Hz Line Cycle Rejection
      11. 9.3.11 Sensor-Excitation Current Sources (IDAC1 and IDAC2)
      12. 9.3.12 Level-Shift Voltage
      13. 9.3.13 General-Purpose Input/Output (GPIO)
      14. 9.3.14 Test DAC (TDAC)
      15. 9.3.15 ADC2 (ADS1263)
        1. 9.3.15.1 ADC2 Inputs
        2. 9.3.15.2 ADC2 PGA
        3. 9.3.15.3 ADC2 Reference
        4. 9.3.15.4 ADC2 Modulator
        5. 9.3.15.5 ADC2 Digital Filter
    4. 9.4 Device Functional Modes
      1. 9.4.1  Conversion Control
        1. 9.4.1.1 Continuous Conversion Mode
        2. 9.4.1.2 Pulse Conversion Mode
        3. 9.4.1.3 ADC2 Conversion Control (ADS1263)
      2. 9.4.2  Conversion Latency
      3. 9.4.3  Programmable Time Delay
      4. 9.4.4  Serial Interface
        1. 9.4.4.1 Chip Select (CS)
        2. 9.4.4.2 Serial Clock (SCLK)
        3. 9.4.4.3 Data Input (DIN)
        4. 9.4.4.4 Data Output/Data Ready (DOUT/DRDY)
        5. 9.4.4.5 Serial Interface Autoreset
      5. 9.4.5  Data Ready Pin (DRDY)
      6. 9.4.6  Conversion Data Software Polling
      7. 9.4.7  Read Conversion Data
        1. 9.4.7.1 Read Data Direct (ADC1 Only)
        2. 9.4.7.2 Read Data by Command
        3. 9.4.7.3 Data-Byte Sequence
          1. 9.4.7.3.1 Status Byte
          2. 9.4.7.3.2 Data Byte Format
          3. 9.4.7.3.3 Checksum Byte (CRC/CHK)
            1. 9.4.7.3.3.1 Checksum Mode (CRC[1:0] = 01h)
          4. 9.4.7.3.4 CRC Mode (CRC[1:0] = 10h)
      8. 9.4.8  ADC Clock Modes
        1. 9.4.8.1 Internal Oscillator
        2. 9.4.8.2 External Clock
        3. 9.4.8.3 Crystal Oscillator
      9. 9.4.9  Calibration
        1. 9.4.9.1 Offset and Full-Scale Calibration
          1. 9.4.9.1.1 Offset Calibration Registers
          2. 9.4.9.1.2 Full-Scale Calibration Registers
        2. 9.4.9.2 ADC1 Offset Self-Calibration (SFOCAL1)
        3. 9.4.9.3 ADC1 Offset System Calibration (SYOCAL1)
        4. 9.4.9.4 ADC2 Offset Self-Calibration ADC2 (SFOCAL2)
        5. 9.4.9.5 ADC2 Offset System Calibration ADC2 (SYOCAL2)
        6. 9.4.9.6 ADC1 Full-Scale System Calibration (SYGCAL1)
        7. 9.4.9.7 ADC2 Full-Scale System Calibration ADC2 (SYGCAL2)
        8. 9.4.9.8 Calibration Command Procedure
        9. 9.4.9.9 User Calibration Procedure
      10. 9.4.10 Reset
        1. 9.4.10.1 Power-On Reset (POR)
        2. 9.4.10.2 RESET/PWDN Pin
        3. 9.4.10.3 Reset by Command
      11. 9.4.11 Power-Down Mode
      12. 9.4.12 Chop Mode
    5. 9.5 Programming
      1. 9.5.1 NOP Command
      2. 9.5.2 RESET Command
      3. 9.5.3 START1, STOP1, START2, STOP2 Commands
      4. 9.5.4 RDATA1, RDATA2 Commands
      5. 9.5.5 SYOCAL1, SYGCAL1, SFOCAL1, SYOCAL2, SYGCAL2, SFOCAL2 Commands
      6. 9.5.6 RREG Command
      7. 9.5.7 WREG Command
    6. 9.6 Register Maps
      1. 9.6.1  Device Identification Register (address = 00h) [reset = x]
      2. 9.6.2  Power Register (address = 01h) [reset = 11h]
      3. 9.6.3  Interface Register (address = 02h) [reset = 05h]
      4. 9.6.4  Mode0 Register (address = 03h) [reset = 00h]
      5. 9.6.5  Mode1 Register (address = 04h) [reset = 80h]
      6. 9.6.6  Mode2 Register (address = 05h) [reset = 04h]
      7. 9.6.7  Input Multiplexer Register (address = 06h) [reset = 01h]
      8. 9.6.8  Offset Calibration Registers (address = 07h, 08h, 09h) [reset = 00h, 00h, 00h]
      9. 9.6.9  Full-Scale Calibration Registers (address = 0Ah, 0Bh, 0Ch) [reset = 40h, 00h, 00h]
      10. 9.6.10 IDACMUX Register (address = 0Dh) [reset = BBh]
      11. 9.6.11 IDACMAG Register (address = 0Eh) [reset = 00h]
      12. 9.6.12 REFMUX Register (address = 0Fh) [reset = 00h]
      13. 9.6.13 TDACP Control Register (address = 10h) [reset = 00h]
      14. 9.6.14 TDACN Control Register (address = 11h) [reset = 00h]
      15. 9.6.15 GPIO Connection Register (address = 12h) [reset = 00h]
      16. 9.6.16 GPIO Direction Register (address = 13h) [reset = 00h]
      17. 9.6.17 GPIO Data Register (address = 14h) [reset = 00h]
      18. 9.6.18 ADC2 Configuration Register (address = 15h) [reset = 00h]
      19. 9.6.19 ADC2 Input Multiplexer Register (address = 16h) [reset = 01h]
      20. 9.6.20 ADC2 Offset Calibration Registers (address = 17h, 18h) [reset = 00h, 00h]
      21. 9.6.21 ADC2 Full-Scale Calibration Registers (address = 19h, 1Ah) [reset = 00h, 40h]
  10. 10Application and Implementation
    1. 10.1 Application Information
      1. 10.1.1 Isolated (or Floated) Inputs
      2. 10.1.2 Single-Ended Measurements
      3. 10.1.3 Differential Measurements
      4. 10.1.4 Input Range
      5. 10.1.5 Input Filtering
        1. 10.1.5.1 Aliasing
      6. 10.1.6 Input Overload
      7. 10.1.7 Unused Inputs and Outputs
      8. 10.1.8 Voltage Reference
      9. 10.1.9 Serial Interface Connections
    2. 10.2 Typical Application
      1. 10.2.1 3-Wire RTD Measurement with Lead-Wire Compensation
        1. 10.2.1.1 Design Requirements
        2. 10.2.1.2 Detailed Design Procedure
        3. 10.2.1.3 Application Curve
    3. 10.3 What To Do and What Not To Do
    4. 10.4 Initialization Setup
  11. 11Power Supply Recommendations
    1. 11.1 Power-Supply Decoupling
    2. 11.2 Analog Power-Supply Clamp
    3. 11.3 Power-Supply Sequencing
  12. 12Layout
    1. 12.1 Layout Guidelines
    2. 12.2 Layout Example
  13. 13Device and Documentation Support
    1. 13.1 Receiving Notification of Documentation Updates
    2. 13.2 Support Resources
    3. 13.3 Trademarks
    4. 13.4 Electrostatic Discharge Caution
    5. 13.5 Glossary

Package Options

Mechanical Data (Package|Pins)
Thermal pad, mechanical data (Package|Pins)
Orderable Information

Read Data Direct (ADC1 Only)

In this method of data retrieval, ADC1 conversion data are shifted out directly from the output shift register. No opcode is necessary. Read data direct requires that no serial activity occur from the time of DRDY low to the readback, or the data are invalid. The serial interface is full duplex; therefore, commands are decoded during the data readback. If no command is intended, keep the DIN pin low during readback. If an input command is sent during readback, the ADC executes the command, and data interruption may result. The data readback operation must be completed 16 fCLK cycles before the next DRDY, or the old data are overwritten with new data. Synchronize the data readback to DRDY or to DOUT/DRDY to make sure the data are read before the next DRDY falling edge.

If new ADC1 conversion data are ready during an ongoing data or register read or write operation, data are not loaded to the output register but are written only to the data holding register. Retrieve the conversion data later from the holding register by sending a read command. However, writing new data to certain registers results in a conversion-cycle restart. Conversion restart clears the contents of the conversion data-holding register; therefore, the previous conversion data are not available. Read the conversion data before the register write operation.

As shown in Figure 9-43, the ADC1 data field is 4, 5, or 6 bytes long, depending on programming. The data field consists of an optional status byte, four bytes of conversion data, and an optional checksum byte. After all the bytes are read, the data-byte sequence is repeated by continuing SCLK. The byte sequence repeats starting with the first byte. In order to help verify error-free communication, read the same data multiple times in each conversion interval and compare.

GUID-34C09B48-47E6-4D62-B559-AC7B22248FFC-low.gif
In Continuous conversion mode, DRDY returns high on the first SCLK falling edge. In Pulse Conversion mode, DRDY stays low until the next conversion is started.
CS can be tied low. If CS is low, DOUT/DRDY asserts low at the same time as DRDY.
Data read must be completed before DOUT/DRDY and DRDY goes high (16 tCLK before new data ready).
The STATUS and CRC/CHK bytes are optional.
The byte sequence repeats by continuing SCLK.
Figure 9-43 Data Read Direct