SBAS920B October   2018  – June 2022 AMC1302-Q1

PRODUCTION DATA  

  1. Features
  2. Applications
  3. Description
  4. Revision History
  5. Pin Configuration and Functions
  6. Specifications
    1. 6.1  Absolute Maximum Ratings
    2. 6.2  ESD Ratings
    3. 6.3  Recommended Operating Conditions
    4. 6.4  Thermal Information
    5. 6.5  Power Ratings
    6. 6.6  Insulation Specifications
    7. 6.7  Safety-Related Certifications
    8. 6.8  Safety Limiting Values
    9. 6.9  Electrical Characteristics
    10. 6.10 Switching Characteristics
    11. 6.11 Timing Diagram
    12. 6.12 Insulation Characteristics Curves
    13. 6.13 Typical Characteristics
  7. Detailed Description
    1. 7.1 Overview
    2. 7.2 Functional Block Diagram
    3. 7.3 Feature Description
      1. 7.3.1 Analog Input
      2. 7.3.2 Isolation Channel Signal Transmission
      3. 7.3.3 Analog Output
    4. 7.4 Device Functional Modes
  8. Application and Implementation
    1. 8.1 Application Information
    2. 8.2 Typical Application
      1. 8.2.1 Design Requirements
      2. 8.2.2 Detailed Design Procedure
        1. 8.2.2.1 Shunt Resistor Sizing
        2. 8.2.2.2 Input Filter Design
        3. 8.2.2.3 Differential to Single-Ended Output Conversion
      3. 8.2.3 Application Curve
    3. 8.3 What to Do and What Not to Do
  9. Power Supply Recommendations
  10. 10Layout
    1. 10.1 Layout Guidelines
    2. 10.2 Layout Example
  11. 11Device and Documentation Support
    1. 11.1 Documentation Support
      1. 11.1.1 Related Documentation
    2. 11.2 Receiving Notification of Documentation Updates
    3. 11.3 Support Resources
    4. 11.4 Trademarks
    5. 11.5 Electrostatic Discharge Caution
    6. 11.6 Glossary
  12. 12Mechanical, Packaging, and Orderable Information

Package Options

Mechanical Data (Package|Pins)
Thermal pad, mechanical data (Package|Pins)
Orderable Information

Revision History

Changes from Revision A (April 2021) to Revision B (June 2022)

  • Added Functional Safety-Capable bullets to Features sectionGo
  • Changed isolation standard from DIN VDE V 0884-11 (VDE V 0884-11) to DIN EN IEC 60747-17 (VDE 0884-17) and updated the Insulation Specifications and Safety-Related Certifications tables accordinglyGo
  • Changed reinforced isolation from 7071 VPK to 7000 VPK Go
  • Changed Applications sectionGo

Changes from Revision * (October 2018) to Revision A (April 2021)

  • Updated the numbering format for tables, figures, and cross-references throughout the document Go
  • Changed VDE certificate in Safety-related certifications Features bullet from DIN V VDE V 0884-11 (VDE V 0884-11) to DIN VDE V 0884-11 Go
  • Changed CMTI specification from 140 kV/µs (typ), 70 kV/µs (min) to 100 kV/µs (min) in Features sectionGo
  • Changed VOS from –100 µV / ±10 µV / 100 µV to –50 µV / ±2.5 µV / 50 µV (min / typ / max)Go
  • Changed EG from –0.3% / ±0.05% / 0.3% to –0.2% / ±0.04% / 0.2% (min / typ / max) Go
  • Changed TCEG from –50 ppm/℃ / ±15 ppm/℃ / 50 ppm/℃  to –35 ppm/℃ / ±3 ppm/℃ / 35 ppm/℃ (min / typ / max) Go
  • Changed VFailsafe from –2.6 V / –2.5 V (typ / max) to –2.63 V / –2.57 V / –2.53 V (min / typ / max)Go
  • Changed CMTI from 55 kV/µs / 80 kV/µs to 100 kV/µs, 150 kV/µs (min / typ) Go
  • Changed VDD1POR from 1.75 V / 2.15 V / 2.7 V to 2.4 V / 2.6 V / 2.8 V (min / typ / max) Go
  • Changed Rise, Fall, and Delay Time Waveforms imageGo
  • Changed Power-Supply Rejection Ratio vs Ripple Frequency figure Go
  • Changed CMTI value in Table 8-1 from 140 kV/µs (typical) to 80 kV/µs (typical) Go