During power-up, VDD must always start and settle before VOFFSET plus tDELAY1 specified in the DMD power supply requirements, VBIAS, and VRESET voltages are applied to the DMD.
During power-up, it is a strict requirement that the voltage difference between VBIAS and VOFFSET must be within the specified limit shown in the recommended operating conditions.
During power-up, there is no requirement for the relative timing of VRESET with respect to VBIAS.
Power supply slew rates during power-up are flexible, provided that the transient voltage levels follow the requirements specified in the absolute maximum ratings, in the recommended operating conditions, and in the DMD power supply requirements.
During power-up, LVCMOS input pins must not be driven high until after VDD has settled at the operating voltage listed in the recommended operating conditions.