SPRSP93 November 2024 F29H850TU , F29H859TU-Q1
ADVANCE INFORMATION
Refer to the PDF data sheet for device specific package drawings
The address mapping tables in this section apply to the following general part numbers: F29H850TU9, F29H859TU8, F29H850DU7, F29H859DU6.
FRI | READ PORT | SIZE | START ADDRESS | END ADDRESS | FLASH BANKS |
---|---|---|---|---|---|
FRI-1 (CPU1 program) | RP0 | 1MB | 0x10000000 | 0x100FFFFF | FLC1.B0/B1 |
RP1 | 1MB | 0x10100000 | 0x101FFFFF | FLC1.B2/B3 | |
RP2 | 1MB | 0x10200000 | 0x102FFFFF | FLC2.B0/B1 | |
RP3 | 1MB | 0x10300000 | 0x103FFFFF | FLC2.B2/B3 | |
FRI-2 (CPU3 program) | RP0 | 1MB | 0x10400000 | 0x104FFFFF | N/A |
RP1 | 1MB | 0x10500000 | 0x105FFFFF | N/A | |
FRI-3 (Update region) | RP0 | 1MB | 0x10600000 | 0x106FFFFF | N/A |
RP1 | 1MB | 0x10700000 | 0x107FFFFF | N/A |
FRI | READ PORT | SIZE | START ADDRESS | END ADDRESS |
FLASH BANKS (SWAP = 0) | FLASH BANKS (SWAP = 1) |
---|---|---|---|---|---|---|
FRI-1 (CPU1 program) | RP0 | 1MB | 0x10000000 | 0x100FFFFF | FLC1.B0/B1 | FLC1.B2/B3 |
RP1 | 1MB | 0x10100000 | 0x101FFFFF | FLC2.B0/B1 | FLC2.B2/B3 | |
RP2 | 1MB | 0x10200000 | 0x102FFFFF | N/A | N/A | |
RP3 | 1MB | 0x10300000 | 0x103FFFFF | N/A | N/A | |
FRI-2 (CPU3 program) | RP0 | 1MB | 0x10400000 | 0x104FFFFF | N/A | N/A |
RP1 | 1MB | 0x10500000 | 0x105FFFFF | N/A | N/A | |
FRI-3 (Update region) | RP0 | 1MB | 0x10600000 | 0x106FFFFF | FLC1.B2/B3 | FLC1.B0/B1 |
RP1 | 1MB | 0x10700000 | 0x107FFFFF | FLC2.B2/B3 | FLC2.B0/B1 |
FRI | READ PORT | SIZE | START ADDRESS | END ADDRESS | FLASH BANKS |
---|---|---|---|---|---|
FRI-1 (CPU1 program) | RP0 | 1MB | 0x10000000 | 0x100FFFFF | FLC1.B0/B1 |
RP1 | 1MB | 0x10100000 | 0x101FFFFF | FLC1.B2/B3 | |
RP2 | 1MB | 0x10200000 | 0x102FFFFF | N/A | |
RP3 | 1MB | 0x10300000 | 0x103FFFFF | N/A | |
FRI-2 (CPU3 program) | RP0 | 1MB | 0x10400000 | 0x104FFFFF | FLC2.B0/B1 |
RP1 | 1MB | 0x10500000 | 0x105FFFFF | FLC2.B2/B3 | |
FRI-3 (Update region) | RP0 | 1MB | 0x10600000 | 0x106FFFFF | N/A |
RP1 | 1MB | 0x10700000 | 0x107FFFFF | N/A |
FRI | READ PORT | SIZE | START ADDRESS | END ADDRESS |
FLASH BANKS (SWAP = 0) | FLASH BANKS (SWAP = 1) |
---|---|---|---|---|---|---|
FRI-1 (CPU1 program) | RP0 | 1MB | 0x10000000 | 0x100FFFFF | FLC1.B0/B1 | FLC1.B2/B3 |
RP1 | 1MB | 0x10100000 | 0x101FFFFF | N/A | N/A | |
RP2 | 1MB | 0x10200000 | 0x102FFFFF | N/A | N/A | |
RP3 | 1MB | 0x10300000 | 0x103FFFFF | N/A | N/A | |
FRI-2 (CPU3 program) | RP0 | 1MB | 0x10400000 | 0x104FFFFF | FLC2.B0/B1 | FLC2.B2/B3 |
RP1 | 1MB | 0x10500000 | 0x105FFFFF | N/A | N/A | |
FRI-3 (Update region) | RP0 | 1MB | 0x10600000 | 0x106FFFFF | FLC1.B2/B3 | FLC1.B0/B1 |
RP1 | 1MB | 0x10700000 | 0x107FFFFF | FLC2.B2/B3 | FLC2.B0/B1 |