SPRSP93 November 2024 F29H850TU , F29H859TU-Q1
ADVANCE INFORMATION
Refer to the PDF data sheet for device specific package drawings
The address mapping tables in this section apply to the following general part numbers: F29H859TM8, F29H850DM7, F29H859DM6.
FRI | READ PORT | SIZE | START ADDRESS | END ADDRESS | FLASH BANKS |
---|---|---|---|---|---|
FRI-1 (CPU1 program) | RP0 | 512KB | 0x10000000 | 0x1007FFFF | FLC1.B0/B1 |
RP1 | 512KB | 0x10100000 | 0x1017FFFF | FLC1.B2/B3 | |
RP2 | 512KB | 0x10200000 | 0x1027FFFF | FLC2.B0/B1 | |
RP3 | 512KB | 0x10300000 | 0x1037FFFF | FLC2.B2/B3 | |
FRI-2 (CPU3 program) | RP0 | 512KB | 0x10400000 | 0x1047FFFF | N/A |
RP1 | 512KB | 0x10500000 | 0x1057FFFF | N/A | |
FRI-3 (Update region) | RP0 | 512KB | 0x10600000 | 0x1067FFFF | N/A |
RP1 | 512KB | 0x10700000 | 0x1077FFFF | N/A |
FRI | READ PORT | SIZE | START ADDRESS | END ADDRESS |
FLASH BANKS (SWAP = 0) | FLASH BANKS (SWAP = 1) |
---|---|---|---|---|---|---|
FRI-1 (CPU1 program) | RP0 | 512KB | 0x10000000 | 0x1007FFFF | FLC1.B0/B1 | FLC1.B2/B3 |
RP1 | 512KB | 0x10100000 | 0x1017FFFF | FLC2.B0/B1 | FLC2.B2/B3 | |
RP2 | 512KB | 0x10200000 | 0x1027FFFF | N/A | N/A | |
RP3 | 512KB | 0x10300000 | 0x1037FFFF | N/A | N/A | |
FRI-2 (CPU3 program) | RP0 | 512KB | 0x10400000 | 0x1047FFFF | N/A | N/A |
RP1 | 512KB | 0x10500000 | 0x1057FFFF | N/A | N/A | |
FRI-3 (Update region) | RP0 | 512KB | 0x10600000 | 0x1067FFFF | FLC1.B2/B3 | FLC1.B0/B1 |
RP1 | 512KB | 0x10700000 | 0x1077FFFF | FLC2.B2/B3 | FLC2.B0/B1 |
FRI | READ PORT | SIZE | START ADDRESS | END ADDRESS | FLASH BANKS |
---|---|---|---|---|---|
FRI-1 (CPU1 program) | RP0 | 512KB | 0x10000000 | 0x1007FFFF | FLC1.B0/B1 |
RP1 | 512KB | 0x10100000 | 0x1017FFFF | FLC1.B2/B3 | |
RP2 | 512KB | 0x10200000 | 0x1027FFFF | N/A | |
RP3 | 512KB | 0x10300000 | 0x1037FFFF | N/A | |
FRI-2 (CPU3 program) | RP0 | 512KB | 0x10400000 | 0x1047FFFF | FLC2.B0/B1 |
RP1 | 512KB | 0x10500000 | 0x1057FFFF | FLC2.B2/B3 | |
FRI-3 (Update region) | RP0 | 512KB | 0x10600000 | 0x1067FFFF | N/A |
RP1 | 512KB | 0x10700000 | 0x1077FFFF | N/A |
FRI | READ PORT | SIZE | START ADDRESS | END ADDRESS |
FLASH BANKS (SWAP = 0) | FLASH BANKS (SWAP = 1) |
---|---|---|---|---|---|---|
FRI-1 (CPU1 program) | RP0 | 512KB | 0x10000000 | 0x1007FFFF | FLC1.B0/B1 | FLC1.B2/B3 |
RP1 | 512KB | 0x10100000 | 0x1017FFFF | N/A | N/A | |
RP2 | 512KB | 0x10200000 | 0x1027FFFF | N/A | N/A | |
RP3 | 512KB | 0x10300000 | 0x1037FFFF | N/A | N/A | |
FRI-2 (CPU3 program) | RP0 | 512KB | 0x10400000 | 0x1047FFFF | FLC2.B0/B1 | FLC2.B2/B3 |
RP1 | 512KB | 0x10500000 | 0x1057FFFF | N/A | N/A | |
FRI-3 (Update region) | RP0 | 512KB | 0x10600000 | 0x1067FFFF | FLC1.B2/B3 | FLC1.B0/B1 |
RP1 | 512KB | 0x10700000 | 0x1077FFFF | FLC2.B2/B3 | FLC2.B0/B1 |