SPRSP93 November 2024 F29H850TU , F29H859TU-Q1
ADVANCE INFORMATION
Refer to the PDF data sheet for device specific package drawings
The following address map tables apply to all part numbers.
FRI | READ PORT | SIZE | START ADDRESS | END ADDRESS | FLASH BANKS |
---|---|---|---|---|---|
FRI-1 (CPU1 program) | RP0 | 4KB | 0x10D81000 | 0x10D81FFF | FLC1.B0/B1 |
RP1 | 4KB | 0x10D85000 | 0x10D85FFF | FLC1.B2/B3 | |
RP2 | 4KB | 0x10D89000 | 0x10D89FFF | FLC2.B0/B1 | |
RP3 | 4KB | 0x10D8D000 | 0x10D8DFFF | FLC2.B2/B3 | |
FRI-2 (CPU3 program)(1) | RP0 | 4KB | 0x10D91000 | 0x10D91FFF | N/A |
RP1 | 4KB | 0x10D95000 | 0x10D95FFF | N/A | |
FRI-3 (Update region) | RP0 | 4KB | 0x10D99000 | 0x10D99FFF | N/A |
RP1 | 4KB | 0x10D9D000 | 0x10D9DFFF | N/A |
FRI | READ PORT | SIZE | START ADDRESS | END ADDRESS |
FLASH BANKS (SWAP = 0) | FLASH BANKS (SWAP = 1) |
---|---|---|---|---|---|---|
FRI-1 (CPU1 program) | RP0 | 4KB | 0x10D81000 | 0x10D81FFF | FLC1.B0/B1 | FLC1.B2/B3 |
RP1 | 4KB | 0x10D85000 | 0x10D85FFF | FLC2.B0/B1 | FLC2.B2/B3 | |
RP2 | 4KB | 0x10D89000 | 0x10D89FFF | N/A | N/A | |
RP3 | 4KB | 0x10D8D000 | 0x10D8DFFF | N/A | N/A | |
FRI-2 (CPU3 program)(1) | RP0 | 4KB | 0x10D91000 | 0x10D91FFF | N/A | N/A |
RP1 | 4KB | 0x10D95000 | 0x10D95FFF | N/A | N/A | |
FRI-3 (Update region) | RP0 | 4KB | 0x10D99000 | 0x10D99FFF | FLC1.B2/B3 | FLC1.B0/B1 |
RP1 | 4KB | 0x10D9D000 | 0x10D9DFFF | FLC2.B2/B3 | FLC2.B0/B1 |
FRI | READ PORT | SIZE | START ADDRESS | END ADDRESS | FLASH BANKS |
---|---|---|---|---|---|
FRI-1 (CPU1 program) | RP0 | 4KB | 0x10D81000 | 0x10D81FFF | FLC1.B0/B1 |
RP1 | 4KB | 0x10D85000 | 0x10D85FFF | FLC1.B2/B3 | |
RP2 | 4KB | 0x10D89000 | 0x10D89FFF | N/A | |
RP3 | 4KB | 0x10D8D000 | 0x10D8DFFF | N/A | |
FRI-2 (CPU3 program)(1) | RP0 | 4KB | 0x10D91000 | 0x10D91FFF | FLC2.B0/B1 |
RP1 | 4KB | 0x10D95000 | 0x10D95FFF | FLC2.B2/B3 | |
FRI-3 (Update region) | RP0 | 4KB | 0x10D99000 | 0x10D99FFF | N/A |
RP1 | 4KB | 0x10D9D000 | 0x10D9DFFF | N/A |
FRI | READ PORT | SIZE | START ADDRESS | END ADDRESS |
FLASH BANKS (SWAP = 0) | FLASH BANKS (SWAP = 1) |
---|---|---|---|---|---|---|
FRI-1 (CPU1 program) | RP0 | 4KB | 0x10D81000 | 0x10D81FFF | FLC1.B0/B1 | FLC1.B2/B3 |
RP1 | 4KB | 0x10D85000 | 0x10D85FFF | N/A | N/A | |
RP2 | 4KB | 0x10D89000 | 0x10D89FFF | N/A | N/A | |
RP3 | 4KB | 0x10D8D000 | 0x10D8DFFF | N/A | N/A | |
FRI-2 (CPU3 program)(1) | RP0 | 4KB | 0x10D91000 | 0x10D91FFF | FLC2.B0/B1 | FLC2.B2/B3 |
RP1 | 4KB | 0x10D95000 | 0x10D95FFF | N/A | N/A | |
FRI-3 (Update region) | RP0 | 4KB | 0x10D99000 | 0x10D99FFF | FLC1.B2/B3 | FLC1.B0/B1 |
RP1 | 4KB | 0x10D9D000 | 0x10D9DFFF | FLC2.B2/B3 | FLC2.B0/B1 |