SNLS564B December 2017 – January 2024 FPC202
PRODUCTION DATA
Refer to the PDF data sheet for device specific package drawings
MIN | NOM | MAX | UNIT | ||
---|---|---|---|---|---|
VDD1 | Supply voltage, VDD1 to GND. DC plus AC power should not exceed these limits. | 3.135 | 3.3 | 3.465 | V |
VDD2 | Host-side interface supply voltage, VDD2 to GND. 1.8 to 3.3 V typical. DC plus AC power should not exceed these limits. | 1.710 | 1.8, 2.5, 3.3 | 3.465 | V |
tRamp-VDD1 | VDD1 supply ramp time, from 0 V to 3.135 V | 1 | ms | ||
tRamp-VDD2 | VDD2 supply ramp time, from 0 V to VDD2 – 5% | 1 | ms | ||
TA | Operating ambient temperature | –40 | 85 | °C | |
TJ | Operating junction temperature | –40 | 125 | °C |