SLLSFJ0F January   2020  – February 2023 ISO6720 , ISO6721 , ISO6721R

PRODUCTION DATA  

  1. Features
  2. Applications
  3. Description
  4. Revision History
  5. Pin Configuration and Functions
  6. Specifications
    1. 6.1  Absolute Maximum Ratings
    2. 6.2  ESD Ratings
    3. 6.3  Recommended Operating Conditions
    4. 6.4  Thermal Information
    5. 6.5  Power Ratings
    6. 6.6  Insulation Specifications
    7. 6.7  Safety-Related Certifications
    8. 6.8  Safety Limiting Values
    9. 6.9  Electrical Characteristics—5-V Supply
    10. 6.10 Supply Current Characteristics—5-V Supply
    11. 6.11 Electrical Characteristics—3.3-V Supply
    12. 6.12 Supply Current Characteristics—3.3-V Supply
    13. 6.13 Electrical Characteristics—2.5-V Supply 
    14. 6.14 Supply Current Characteristics—2.5-V Supply
    15. 6.15 Electrical Characteristics—1.8-V Supply
    16. 6.16 Supply Current Characteristics—1.8-V Supply
    17. 6.17 Switching Characteristics—5-V Supply
    18. 6.18 Switching Characteristics—3.3-V Supply
    19. 6.19 Switching Characteristics—2.5-V Supply
    20. 6.20 Switching Characteristics—1.8-V Supply
    21. 6.21 Insulation Characteristics Curves
    22. 6.22 Typical Characteristics
  7. Parameter Measurement Information
  8. Detailed Description
    1. 8.1 Overview
    2. 8.2 Functional Block Diagram
    3. 8.3 Feature Description
      1. 8.3.1 Electromagnetic Compatibility (EMC) Considerations
    4. 8.4 Device Functional Modes
      1. 8.4.1 Device I/O Schematics
  9. Application and Implementation
    1. 9.1 Application Information
    2. 9.2 Typical Application
      1. 9.2.1 Design Requirements
      2. 9.2.2 Detailed Design Procedure
      3. 9.2.3 Application Curve
    3. 9.3 Insulation Lifetime
  10. 10Power Supply Recommendations
  11. 11Layout
    1. 11.1 Layout Guidelines
      1. 11.1.1 PCB Material
    2. 11.2 Layout Example
  12. 12Device and Documentation Support
    1. 12.1 Device Support
      1. 12.1.1 Development Support
    2. 12.2 Documentation Support
      1. 12.2.1 Related Documentation
    3. 12.3 Receiving Notification of Documentation Updates
    4. 12.4 Support Resources
    5. 12.5 Trademarks
    6. 12.6 Electrostatic Discharge Caution
    7. 12.7 Glossary
  13. 13Mechanical, Packaging, and Orderable Information

Package Options

Mechanical Data (Package|Pins)
Thermal pad, mechanical data (Package|Pins)
Orderable Information

Safety-Related Certifications

VDE CSA UL CQC TUV
Certified according to DIN EN IEC 60747-17 (VDE 0884-17) Certified according to IEC 62368-1, IEC 61010-1 and IEC 60601 Certified according to UL 1577 Component Recognition Program Certified according to GB 4943.1 Certified according to EN 61010-1 and EN 62368-1
Maximum transient isolation voltage, 4242 VPK;
Maximum repetitive peak isolation voltage, 637 VPK;
Maximum surge isolation voltage, 6500 VPK
400 VRMS basic insulation per CSA 62368-1 and IEC 62368-1; 300 VRMS basic insulation per CSA 61010-1 and IEC 61010-1 (pollution degree 2, material group III)

1 MOPP (Means of Patient Protection) per CSA 60601-1 and IEC 60601-1, 250 VRMS (D-8) max working voltage
Single protection,
3000 VRMS
Basic insulation, Altitude ≤ 5000 m, Tropical Climate,
250 VRMS maximum working voltage
3000 VRMS (D-8) Basic insulation per EN 61010-1 up to working voltage of 300 VRMS (D-8)
3000 VRMS (D-8) basic insulation per EN 62368-1 up to working voltage of 400 VRMS (D-8)
Certificate number: 40047657 Master contract number: 220991 File number: E181974 Certificate number: CQC21001305151 Client ID number: 077311