SLLSFC6D November   2021  – January 2023 ISOUSB111

PRODUCTION DATA  

  1. Features
  2. Applications
  3. Description
  4. Revision History
  5. Pin Configuration and Functions
  6. Specifications
    1. 6.1  Absolute Maximum Ratings
    2. 6.2  ESD Ratings
    3. 6.3  Recommended Operating Conditions
    4. 6.4  Thermal Information
    5. 6.5  Power Ratings
    6. 6.6  Insulation Specifications
    7. 6.7  Safety-Related Certifications
    8. 6.8  Safety Limiting Values
    9. 6.9  Electrical Characteristics
    10. 6.10 Switching Characteristics
    11. 6.11 Insulation Characteristics Curves
    12. 6.12 Typical Characteristics
  7. Parameter Measurement Information
    1. 7.1 Test Circuits
  8. Detailed Description
    1. 8.1 Overview
    2. 8.2 Functional Block Diagram
    3. 8.3 Feature Description
      1. 8.3.1 Power Supply Options
      2. 8.3.2 Power Up
      3. 8.3.3 Symmetric Operation, Dual-Role Port and Role-Reversal
      4. 8.3.4 Connect and Speed Detection
      5. 8.3.5 Disconnect Detection
      6. 8.3.6 Reset
      7. 8.3.7 LS/FS Message Traffic
      8. 8.3.8 L2 Power Management State (Suspend) and Resume
      9. 8.3.9 L1 Power Management State (Sleep) and Resume
    4. 8.4 Device Functional Modes
  9. Power Supply Recommendations
  10. 10Application and Implementation
    1. 10.1 Typical Application
      1. 10.1.1 Isolated Host or Hub
      2. 10.1.2 Isolated Peripheral - Self-Powered
      3. 10.1.3 Isolated Peripheral - Bus-Powered
      4. 10.1.4 Application Curve
        1. 10.1.4.1 Insulation Lifetime
  11. 11Layout
    1. 11.1 Layout Guidelines
      1. 11.1.1 Layout Example
      2. 11.1.2 PCB Material
  12. 12Device and Documentation Support
    1. 12.1 Documentation Support
      1. 12.1.1 Related Documentation
    2. 12.2 Receiving Notification of Documentation Updates
    3. 12.3 Support Resources
    4. 12.4 Trademarks
    5. 12.5 Electrostatic Discharge Caution
    6. 12.6 Glossary
  13. 13Mechanical, Packaging, and Orderable Information
    1. 13.1 Tape and Reel Information

Package Options

Mechanical Data (Package|Pins)
Thermal pad, mechanical data (Package|Pins)
Orderable Information

Safety-Related Certifications

VDE CSA UL CQC TUV
Certified according to DIN EN IEC 60747-17 (VDE 0884-17) Certified according to IEC 61010-1, IEC 62368-1 and IEC 60601-1 Recognized under UL 1577 Component Recognition Program Certified according to GB 4943.1 Certified according to EN 61010-1 and EN 62368-1
Reinforced Insulation; Maximum transient isolation voltage,

ISOUSB111: 7071 VPK
Maximum repetitive peak isolation voltage, 2121 VPK;
Maximum surge isolation voltage,
ISOUSB111: 12800 VPK (Reinforced)
 
Reinforced insulation per CSA 62368-1 and IEC 62368-1
ISOUSB111: 800 VRMS 

Maximum working voltage (pollution degree 2, material group I);
ISOUSB111: 2 MOPP

----------------

(Means of Patient Protection) per CSA 60601-1 and IEC 60601-1, 250 VRMS maximum working voltage
Single protection,

ISOUSB111: 5000 VRMS
 
Reinforced insulation, Altitude ≤ 5000 m, Tropical Climate,
700 VRMS maximum working voltage
5000 VRMS Reinforced insulation per EN 61010-1 up to working voltage of 600 VRMS                      
----------------
5000 VRMS Reinforced insulation per EN 62368-1 up to working voltage of 800 VRMS
 
Certificate number: 40040142
 
Master contract: 220991 File number: E181974 Certificate: CQC15001121716 Client ID: 77311