SLVSFF1B December 2021 – December 2022 LM5123-Q1
PRODUCTION DATA
Refer to the PDF data sheet for device specific package drawings
The programmable VOUT range is selected during the device configuration and it cannot be changed until the user reconfigures the device. Lower VOUT range (5 V to 20 V) is selected if the resistance from VREF to AGND (RVREFT + RVREFB) is in the range of 75 kΩ to 100 kΩ during the device configuration. Upper VOUT range (15 V to 57 V) is selected if the resistance from VREF to AGND is in the range of 20 kΩ to 35 kΩ during the device configuration. The accuracy of the VOUT regulation is specified within the selected range.