SLVSES8A October 2020 – December 2020 LM5127-Q1
PRODUCTION DATA
DEVICE CONFIGURATON | NOTES | |||
---|---|---|---|---|
Boost/SEPIC + Buck + Buck | Configuration is latched during initial start-up. | |||
Boost/SEPIC + 2PH Buck | Configuration is latched during initial start-up. | |||
Buck + Buck + Buck | Configuration is latched during initial start-up. | |||
Buck + 2PH Buck | Configuration is latched during initial start-up. | |||
OUTPUT REGULATION SELECTION | NOTES | |||
Fixed 3.3 V | Supported in buck. The regulation target is latched during initial start-up. | |||
Fixed 5.0 V | Supported in buck. The regulation target is latched during initial start-up. | |||
Adjustable from 0.8 to 42 V | Supported in boost and buck. Dynamically programmable during operation. | |||
LIGHT LOAD SWITCHING MODE | NOTES | |||
Skip mode | Apply to all channels. The mode is latched during initial start-up. | |||
FPWM mode | Apply to all channels. The mode is latched during initial start-up. | |||
DE operation in FPWM mode | Dynamically changeable between FPWM and DE during operation. | |||
HICCUP MODE PROTECTION | NOTES | |||
Hiccup mode protection | Apply to all channels. The mode is latched during initial start-up. | |||
Latch-off mode protection | Apply to all channels. The mode is latched during initial start-up. | |||
Cycle-by-cycle current limit | Apply to all channels. The mode is latched during initial start-up. | |||
SWITCHING FREQUENCY | NOTES | |||
RT programming | Apply to all channels. Dynamically programmable during operation. | |||
SYNC | Apply to all channels. Dynamically programmable during operation. Dynamically changeable between SYNC and RT switching during operation. | |||
DITHER | Apply to all channels. Dynamically programmable during operation. Dynamically changeable between DITHER and RT switching during operation. | |||
FUNCTION | NOTES | |||
Enable | Dedicated pin per channel | |||
Soft-start | Dedicated pin per channel. SS3 is disabled in dual-phase buck. | |||
PGOOD | Dedicated pin per channel. PGOOD3 is disabled in dual-phase buck. | |||
DEVICE/CHANNEL STATUS | NOTES | |||
Shutdown mode | Apply to all channels. | |||
Configuration mode | Apply to all channels. | |||
Active mode | Each channel works individually. | |||
Sleep mode | Each channel works individually. | |||
Deep sleep mode | Apply to all channels. | |||
VCC HOLD mode | Apply to all channels. | |||
PULSE WIDTH MODULATION TYPE | NOTES | |||
Normal PWM operation | Available in both boost and buck. | |||
Pulse skipping operation | Available in both boost and buck. | |||
Bypass mode operation | Available in boost. | |||
LDO mode operation | Available in buck. | |||
SPECIAL DEVICE/CHANNEL STATUS | NOTES | |||
Hiccup mode off | Each channel enters hiccup mode off individually. CH2 and CH3 enter hiccup mode off together in dual-phase buck. Automatic restart if hiccup mode is selected. | |||
OVP protection | Each channel stops switching individually. Disabled in boost. Restarts naturally | |||
Thermal Shutdown | All channels shutdown. Restarts naturally. |