6.1 Absolute Maximum Ratings
over operating free-air temperature range (unless otherwise noted)(1)
PARAMETER |
MIN |
MAX |
UNIT |
VIN to PGND |
0 |
80 |
V |
VIN to PGND (pulsed, 100-ms max duration)(2) |
|
100 |
V |
HB to AGND |
-0.3 |
86 |
V |
HS to AGND |
-5 |
80 |
V |
HI to AGND |
-0.3 |
12 |
V |
LI to AGND |
-0.3 |
12 |
V |
VCC to AGND |
-0.3 |
6 |
V |
HB to HS |
-0.3 |
6 |
V |
HB to VCC |
0 |
80 |
V |
SW to PGND |
-5 |
80 |
V |
IOUT from SW pin |
|
10 |
A |
Junction Temperature, TJ |
-40 |
125 |
°C |
Storage Temperature, Tstg |
-40 |
150 |
°C |
(1) Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings only, which do not imply functional operation of the device at these or any other conditions beyond those indicated under Recommended Operating Conditions. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) Device can withstand 1000 pulses up to 100V of 100ms duration and less than 1% duty cycle over its lifetime.