Over the recommended operating junction temperature range of –40°C to 150°C (unless otherwise noted) (1) (2)
|
MIN |
TYP |
MAX |
UNIT |
Input voltage |
Input voltage range after start-up |
3.6 |
|
65 |
V |
Output voltage |
Output voltage range for adjustable output variants |
1 |
|
16 |
V |
Output current |
LMR36500 load current range (3) |
0 |
|
50 |
mA |
Frequency setting |
Selectable frequency range with RT (RT variant only) |
0.2 |
|
2.2 |
MHz |
Temperature |
TJ juction temperature |
–40 |
|
150 |
°C |
(1) Recommended operating conditions indicate conditions for which the device is intended to be functional, but do not ensure specific performance limits. For ensured specifications, see Electrical Characteristics table.
(3) Maximum continuous DC current can be derated when operating with high switching frequency or high ambient temperature. See Application section for details.