SBAS884A March 2020 – June 2020 PCM6240-Q1 , PCM6260-Q1 , PCM6340-Q1 , PCM6360-Q1
PRODUCTION DATA.
This register is the live Interrupt status register for channel 1 fault diagnostic
7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
CH1_LIVE[7] | CH1_LIVE[6] | CH1_LIVE[5] | CH1_LIVE[4] | CH1_LIVE[3] | CH1_LIVE[2] | CH1_LIVE[1] | CH1_LIVE[0] |
R-0h | R-0h | R-0h | R-0h | R-0h | R-0h | R-0h | R-0h |
Bit | Field | Type | Reset | Description |
---|---|---|---|---|
7 | CH1_LIVE[7] | R | 0h | Channel 1 open input fault status.
0d = No open input detected 1d = Open input detected |
6 | CH1_LIVE[6] | R | 0h | Channel 1 input pair short fault status.
0d = No input pair short detected 1d = Input short to each other detected |
5 | CH1_LIVE[5] | R | 0h | Channel 1 IN1P short to ground fault status.
0d = IN1P no short to ground detected 1d = IN1P short to ground detected |
4 | CH1_LIVE[4] | R | 0h | Channel 1 IN1M short to ground fault status.
0d = IN1M no short to ground detected 1d = IN1M short to ground detected |
3 | CH1_LIVE[3] | R | 0h | Channel 1 IN1P short to MICBIAS fault status.
0d = IN1P no short to MICBIAS detected 1d = IN1P short to MICBIAS detected |
2 | CH1_LIVE[2] | R | 0h | Channel 1 IN1M short to MICBIAS fault status.
0d = IN1M no short to MICBIAS detected 1d = IN1M short to MICBIAS detected |
1 | CH1_LIVE[1] | R | 0h | Channel 1 IN1P short to VBAT_IN fault status.
0d = IN1P no short to VBAT_IN detected 1d = IN1P short to VBAT_IN detected |
0 | CH1_LIVE[0] | R | 0h | Channel 1 IN1M short to VBAT_IN fault status.
0d = IN1M no short to VBAT_IN detected 1d = IN1M short to VBAT_IN detected |