over operating free−air temperature range unless otherwise noted(1)
|
MIN |
MAX |
UNIT |
VCC
|
Supply voltage range, (see (2)) |
−0.5 |
7 |
V |
(A or B) |
Voltage range at any bus terminal |
−15 |
15 |
V |
VI (D, DE, R or RE) |
Input voltage |
−0.3 |
7 |
V |
IO
|
Receiver output current |
|
±20 |
mA |
|
Continuous total power dissipation |
See Dissipation Rating table |
(1) Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) All voltage values, except differential I/O bus voltages, are with respect to network ground terminal.