SLOSE88 December 2024 TAS6754-Q1
ADVANCE INFORMATION
At power-up, the PD pin is recommended to be kept low until all three power supply rails (VBAT, PVDD, DVDD) are within the Recommended Operating Conditions.
When all power rails are applied and ready, releasing the PD pin will power up the internal digital circuitry. After releasing the PD pin a minimum 4 ms wait time is recommended before releasing the STBY pin. Releasing the STBY pin powers up the internal analog circuitry. If this sequence is not possible and PD as well as STBY have to be released at the same time, the following state transition might take up to 6 ms in which the device powers up the analog circuitry and ensures a proper internal boot procedure.
Any time a power fault happens after the analog circuitry is powered up (VBAT ready and STBY released), TAS6754-Q1 will leave PLAY or other states and go back to the Auto Recovery (AUTOREC) State, until the power fault disappears.