For R
SET in the 0-5 kΩ range, TIOL112(x) can source/sink 500 mA required for wake-up pulse generation in IO-link applications. For R
SET in the 0-5 kΩ range, TIOL112(x) also activates a pull-down current source (I
LLM) when the driver is disabled. Min and max curves specified by design and characterization across temperature and process variation.