SNVSB04C March 2019 – December 2021 TLV4021 , TLV4031 , TLV4041 , TLV4051
PRODUCTION DATA
Do connect a 100 nF decoupling capacitor from (V+) to (V-) for best system performance.
If the monitored voltage is noisy, do connect a decoupling capacitor from the comparator input (IN) to (V-).
Don't use resistors for the voltage divider that cause the current through them to be less than 100 times the input current of the comparator without also accounting for the impact on accuracy.