SBOSA24B July   2023  – December 2024 TMCS1123

PRODUCTION DATA  

  1.   1
  2. Features
  3. Applications
  4. Description
  5. Device Comparison
  6. Pin Configuration and Functions
  7. Specifications
    1. 6.1 Absolute Maximum Ratings
    2. 6.2 ESD Ratings
    3. 6.3 Recommended Operating Conditions
    4. 6.4 Thermal Information
    5. 6.5 Insulation Specifications
    6. 6.6 Electrical Characteristics
    7. 6.7 Typical Characteristics
  8. Parameter Measurement Information
    1. 7.1 Accuracy Parameters
      1. 7.1.1 Sensitivity Error
      2. 7.1.2 Offset Error and Offset Error Drift
      3. 7.1.3 Nonlinearity Error
      4. 7.1.4 Power Supply Rejection Ratio
      5. 7.1.5 Common-Mode Rejection Ratio
      6. 7.1.6 External Magnetic Field Errors
    2. 7.2 Transient Response Parameters
      1. 7.2.1 CMTI, Common-Mode Transient Immunity
    3. 7.3 Safe Operating Area
      1. 7.3.1 Continuous DC or Sinusoidal AC Current
      2. 7.3.2 Repetitive Pulsed Current SOA
      3. 7.3.3 Single Event Current Capability
  9. Detailed Description
    1. 8.1 Overview
    2. 8.2 Functional Block Diagram
    3. 8.3 Feature Description
      1. 8.3.1 Current Input
      2. 8.3.2 Ambient Field Rejection
      3. 8.3.3 High-Precision Signal Chain
        1. 8.3.3.1 Temperature Stability
        2. 8.3.3.2 Lifetime and Environmental Stability
      4. 8.3.4 Internal Reference Voltage
      5. 8.3.5 Current-Sensing Measurable Ranges
      6. 8.3.6 Overcurrent Detection
        1. 8.3.6.1 Setting The User Configurable Overcurrent Threshold
          1. 8.3.6.1.1 Setting Overcurrent Threshold Using Power Supply Voltage
          2. 8.3.6.1.2 Setting Overcurrent Threshold Using Internal Reference Voltage
          3. 8.3.6.1.3 Setting Overcurrent Threshold Example
        2. 8.3.6.2 Overcurrent Output Response
        3. 8.3.6.3 Overcurrent Detection MASK Time
      7. 8.3.7 Sensor Diagnostics
        1. 8.3.7.1 Thermal Alert
        2. 8.3.7.2 Sensor Alert
    4. 8.4 Device Functional Modes
      1. 8.4.1 Power-Down Behavior
  10. Application and Implementation
    1. 9.1 Application Information
      1. 9.1.1 Total Error Calculation Examples
        1. 9.1.1.1 Room-Temperature Error Calculations
        2. 9.1.1.2 Full-Temperature Range Error Calculations
    2. 9.2 Typical Application
      1. 9.2.1 Design Requirements
      2. 9.2.2 Detailed Design Procedure
      3. 9.2.3 Application Curve
    3. 9.3 Power Supply Recommendations
    4. 9.4 Layout
      1. 9.4.1 Layout Guidelines
      2. 9.4.2 Layout Example
  11. 10Device and Documentation Support
    1. 10.1 Device Nomenclature
    2. 10.2 Device Support
      1. 10.2.1 Development Support
    3. 10.3 Documentation Support
      1. 10.3.1 Related Documentation
    4. 10.4 Receiving Notification of Documentation Updates
    5. 10.5 Support Resources
    6. 10.6 Trademarks
    7. 10.7 Electrostatic Discharge Caution
    8. 10.8 Glossary
  12. 11Revision History
  13. 12Mechanical, Packaging, and Orderable Information

Package Options

Refer to the PDF data sheet for device specific package drawings

Mechanical Data (Package|Pins)
  • DVG|10
Thermal pad, mechanical data (Package|Pins)
Orderable Information

Device Comparison

Table 4-1 Device Comparison
PRODUCT(3) SENSITIVITY ZERO CURRENT OUTPUT VOLTAGE IIN LINEAR MEASUREMENT RANGE(1)
VS = 5V VS = 3.3V
TMCS1123A1A 25mV/A 2.5V ±96A(2) –96A to 28A(2)
TMCS1123A2A 50mV/A ±48A(2) –48A to 14A(2)
TMCS1123A3A 75mV/A ±32A –32A to 9.3A
TMCS1123A4A 100mV/A ±24A –24A to 7A
TMCS1123A5A 150mV/A ±16A –16A to 4.7A
TMCS1123B1A 25mV/A 1.65V –62A to 130A(2) ±62A(2)
TMCS1123B2A 50mV/A –31A to 65A(2) ±31A
TMCS1123B3A 75mV/A –20.7A to 43.3A(2) ±20.7A
TMCS1123B4A 100mV/A –15.5A to 32.5A ±15.5A
TMCS1123B5A 150mV/A –10.3A to 21.7A ±10.3A
TMCS1123D71 38.5mV/A 1.5V –36.3A to 88.3A(2) –36.3A to 44.1A(2)
TMCS1123C1A 25mV/A 0.33V –9.2A to 183A(2) –9.2A to 115A(2)
TMCS1123C2A 50mV/A –4.6A to 91.4A(2) –4.6A to 57.4A(2)
TMCS1123C3A 75mV/A –3.1A to 60.9A(2) –3.1A to 38.3A(2)
TMCS1123C4A 100mV/A –2.3A to 45.7A(2) –2.3A to 28.7A
TMCS1123C5A 150mV/A –1.5A to 30.5A –1.5A to 19.1A
Linear range limited by the maximum output swing to power supply (3V to 5.5V) and ground, not by thermal limitations.
Current levels must remain below both allowable continuous DC/RMS and transient peak current safe operating areas to not exceed device thermal limits. See the Safe Operating Area section.
For more information on the device name and device options, see the Device Nomenclature section.
Table 4-2 Specialty Devices
PRODUCT SPECIAL FEATURE DESCRIPTION
TMCS1123D71 Extended overcurrent detection response prevents unwanted interrupts due to noise or interferrence.(1)
Overcurrent output is asserted after a sustained overcurrent event lasting longer than specified MASK time as shown in Section 8.3.6.3.