SBOS854F March   2018  – June 2024 TMP1075

PRODUCTION DATA  

  1.   1
  2. Features
  3. Applications
  4. Description
  5. Device Comparison
  6. Pin Configuration and Functions
  7. Specifications
    1. 6.1  Absolute Maximum Ratings
    2. 6.2  ESD Ratings
    3. 6.3  Recommended Operating Conditions
    4. 6.4  Thermal Information
    5. 6.5  Electrical Characteristics:TMP1075
    6. 6.6  Electrical Characteristics: TMP1075N
    7. 6.7  Timing Requirements:TMP1075
    8. 6.8  Timing Requirements: TMP1075N
    9. 6.9  Switching Characteristics
    10. 6.10 Timing Diagrams
    11. 6.11 Typical Characteristics
  8. Detailed Description
    1. 7.1 Overview
    2. 7.2 Functional Block Diagram
    3. 7.3 Feature Description
      1. 7.3.1 Digital Temperature Output
      2. 7.3.2 I2C and SMBus Serial Interface
        1. 7.3.2.1  Bus Overview
        2. 7.3.2.2  Serial Bus Address
        3. 7.3.2.3  Pointer Register
          1. 7.3.2.3.1 Pointer Register Byte [reset = 00h]
        4. 7.3.2.4  Writing and Reading to the TMP1075
        5. 7.3.2.5  Operation Mode
          1. 7.3.2.5.1 Receiver Mode
          2. 7.3.2.5.2 Transmitter Mode
        6. 7.3.2.6  SMBus Alert Function
        7. 7.3.2.7  General Call- Reset Function
        8. 7.3.2.8  High-Speed Mode (HS)
        9. 7.3.2.9  Coexists in I3C Mixed Fast Mode
        10. 7.3.2.10 Time-Out Function
      3. 7.3.3 Timing Diagrams
      4. 7.3.4 Two-Wire Timing Diagrams
    4. 7.4 Device Functional Modes
      1. 7.4.1 Shutdown Mode (SD)
      2. 7.4.2 One-Shot Mode (OS)
      3. 7.4.3 Continuous Conversion Mode (CC)
      4. 7.4.4 Thermostat Mode (TM)
        1. 7.4.4.1 Comparator Mode (TM = 0)
        2. 7.4.4.2 Interrupt Mode (TM = 1)
        3. 7.4.4.3 Polarity Mode (POL)
    5. 7.5 Register Map
      1. 7.5.1 Register Descriptions
        1. 7.5.1.1 Temperature Register (address = 00h) [default reset = 0000h]
        2. 7.5.1.2 Configuration Register (address = 01h) [default reset = 00FFh (60A0h TMP1075N)]
        3. 7.5.1.3 Low Limit Register (address = 02h) [default reset = 4B00h]
        4. 7.5.1.4 High Limit Register (address = 03h) [default reset = 5000h]
        5. 7.5.1.5 Device ID Register (address = 0Fh) [default reset = 7500]
  9. Application and Implementation
    1. 8.1 Application Information
    2. 8.2 Typical Application
      1. 8.2.1 Design Requirements
      2. 8.2.2 Detailed Design Procedure
        1. 8.2.2.1 Migrating From the xx75 Device Family
      3. 8.2.3 Application Curve
    3. 8.3 Power Supply Recommendations
    4. 8.4 Layout
      1. 8.4.1 Layout Guidelines
      2. 8.4.2 Layout Example
  10. Device and Documentation Support
    1. 9.1 Documentation Support
      1. 9.1.1 Related Documentation
    2. 9.2 Receiving Notification of Documentation Updates
    3. 9.3 Support Resources
    4. 9.4 Trademarks
    5. 9.5 Electrostatic Discharge Caution
    6. 9.6 Glossary
  11. 10Revision History
  12. 11Mechanical, Packaging, and Orderable Information

Package Options

Mechanical Data (Package|Pins)
Thermal pad, mechanical data (Package|Pins)
Orderable Information

Comparator Mode (TM = 0)

In comparator mode (TM = 0), the ALERT pin becomes active when the temperature equals or exceeds the value in THIGH for a consecutive number of Fault Queue bits [F1:F0]. The ALERT pin remains active until the temperature falls below the indicated TLOW value for the same number of faults.

The difference between the two limits acts as a hysteresis on the comparator output, and a fault counter prevents false alerts as a result of system noise. The SMBus Alert response function is ignored in the comparator mode.