SNIS217C december   2020  – may 2023 TMP139

PRODUCTION DATA  

  1. Features
  2. Applications
  3. Description
  4. Revision History
  5. Pin Configuration and Functions
  6. Specifications
    1. 6.1 Absolute Maximum Ratings
    2. 6.2 ESD Ratings
    3. 6.3 Recommended Operating Conditions
    4. 6.4 Thermal Information
    5. 6.5 Electrical Characteristics
    6. 6.6 Timing Requirements
    7. 6.7 Switching Characteristics
    8. 6.8 Timing Diagrams
    9. 6.9 Typical Characteristics
  7. Detailed Description
    1. 7.1 Overview
    2. 7.2 Functional Block Diagram
    3. 7.3 Feature Description
      1. 7.3.1 Power-Up Sequence
      2. 7.3.2 Power-Down and Device Reset
      3. 7.3.3 Temperature Result and Limits
      4. 7.3.4 Bus Reset
      5. 7.3.5 Interrupt Generation
      6. 7.3.6 Parity Error Check
      7. 7.3.7 Packet Error Check
    4. 7.4 Device Functional Modes
      1. 7.4.1 Conversion Mode
      2. 7.4.2 Serial Address
      3. 7.4.3 I2C Mode Operation
        1. 7.4.3.1 Host I2C Write Operation
        2. 7.4.3.2 Host I2C Read Operation
        3. 7.4.3.3 Host I2C Read Operation in Default Read Address Pointer Mode
        4. 7.4.3.4 Switching from I2C Mode to I3C Basic Mode
      4. 7.4.4 I3C Basic Mode Operation
        1. 7.4.4.1 Host I3C Write Operation without PEC
        2. 7.4.4.2 Host I3C Write Operation with PEC
        3. 7.4.4.3 Host I3C Read Operation without PEC
        4. 7.4.4.4 Host I3C Read Operation with PEC
        5. 7.4.4.5 Host I3C Read Operation in Default Read Address Pointer Mode
      5. 7.4.5 In Band Interrupt
        1. 7.4.5.1 In Band Interrupt Arbitration Rules
        2. 7.4.5.2 In Band Interrupt Bus Transaction
      6. 7.4.6 Common Command Codes Support
        1. 7.4.6.1 ENEC CCC
        2. 7.4.6.2 DISEC CCC
        3. 7.4.6.3 RSTDAA CCC
        4. 7.4.6.4 SETAASA CCC
        5. 7.4.6.5 GETSTATUS CCC
        6. 7.4.6.6 DEVCAP CCC
        7. 7.4.6.7 SETHID CCC
        8. 7.4.6.8 DEVCTRL CCC
      7. 7.4.7 I/O Operation
      8. 7.4.8 Timing Diagrams
    5. 7.5 Programming
      1. 7.5.1 Enabling Interrupt Mechanism
      2. 7.5.2 Clearing Interrupt
    6. 7.6 Register Map
  8. Application and Implementation
    1. 8.1 Application Information
    2. 8.2 Typical Application
      1. 8.2.1 Design Requirements
      2. 8.2.2 Detailed Design Procedure
      3. 8.2.3 Application Curves
    3. 8.3 Power Supply Recommendations
    4. 8.4 Layout
      1. 8.4.1 Layout Guidelines
      2. 8.4.2 Layout Example
  9. Device and Documentation Support
    1. 9.1 Receiving Notification of Documentation Updates
    2. 9.2 Support Resources
    3. 9.3 Trademarks
    4. 9.4 Electrostatic Discharge Caution
    5. 9.5 Glossary
  10. 10Mechanical, Packaging, and Orderable Information

Package Options

Refer to the PDF data sheet for device specific package drawings

Mechanical Data (Package|Pins)
  • YAH|6
Thermal pad, mechanical data (Package|Pins)
Orderable Information

GETSTATUS CCC

The GETSTATUS CCC is issued by the host controller to the TMP139 to get the status of any pending parity error, PEC error, or interrupt event. Once the GETSTATUS is received, the TMP139 shall not clear the status and host must issue additional transactions on the bus to clear the status flags individually or by writing 1'b1 to the MR27 register CLR_GLOBAL bit.

The command is issued only in direct mode as shown in Figure 7-36, when PEC is disabled, and in Figure 7-37, when PEC is enabled. In the latter case, the host controller shall append the PEC byte calculated on all bytes except the byte with 7'h7E and R/W=0 after the Start or Repeated Start. The TMP139 calculates the PEC on the data bytes that are sent to the host.

GUID-20200722-CA0I-K3WH-SHNT-R5RZ5JPXRJZZ-low.gifFigure 7-36 GETSTATUS CCC Direct
GUID-20200722-CA0I-GHGJ-XX3G-RDP8Q7WKT2ZN-low.gifFigure 7-37 GETSTATUS CCC Direct with PEC Enabled
Note:

TMP139 NACKs the GETSTATUS CCC if the previous transaction has a parity or PEC error and the host starts the transaction with a Repeated Start.