SNIS217C december   2020  – may 2023 TMP139

PRODUCTION DATA  

  1. Features
  2. Applications
  3. Description
  4. Revision History
  5. Pin Configuration and Functions
  6. Specifications
    1. 6.1 Absolute Maximum Ratings
    2. 6.2 ESD Ratings
    3. 6.3 Recommended Operating Conditions
    4. 6.4 Thermal Information
    5. 6.5 Electrical Characteristics
    6. 6.6 Timing Requirements
    7. 6.7 Switching Characteristics
    8. 6.8 Timing Diagrams
    9. 6.9 Typical Characteristics
  7. Detailed Description
    1. 7.1 Overview
    2. 7.2 Functional Block Diagram
    3. 7.3 Feature Description
      1. 7.3.1 Power-Up Sequence
      2. 7.3.2 Power-Down and Device Reset
      3. 7.3.3 Temperature Result and Limits
      4. 7.3.4 Bus Reset
      5. 7.3.5 Interrupt Generation
      6. 7.3.6 Parity Error Check
      7. 7.3.7 Packet Error Check
    4. 7.4 Device Functional Modes
      1. 7.4.1 Conversion Mode
      2. 7.4.2 Serial Address
      3. 7.4.3 I2C Mode Operation
        1. 7.4.3.1 Host I2C Write Operation
        2. 7.4.3.2 Host I2C Read Operation
        3. 7.4.3.3 Host I2C Read Operation in Default Read Address Pointer Mode
        4. 7.4.3.4 Switching from I2C Mode to I3C Basic Mode
      4. 7.4.4 I3C Basic Mode Operation
        1. 7.4.4.1 Host I3C Write Operation without PEC
        2. 7.4.4.2 Host I3C Write Operation with PEC
        3. 7.4.4.3 Host I3C Read Operation without PEC
        4. 7.4.4.4 Host I3C Read Operation with PEC
        5. 7.4.4.5 Host I3C Read Operation in Default Read Address Pointer Mode
      5. 7.4.5 In Band Interrupt
        1. 7.4.5.1 In Band Interrupt Arbitration Rules
        2. 7.4.5.2 In Band Interrupt Bus Transaction
      6. 7.4.6 Common Command Codes Support
        1. 7.4.6.1 ENEC CCC
        2. 7.4.6.2 DISEC CCC
        3. 7.4.6.3 RSTDAA CCC
        4. 7.4.6.4 SETAASA CCC
        5. 7.4.6.5 GETSTATUS CCC
        6. 7.4.6.6 DEVCAP CCC
        7. 7.4.6.7 SETHID CCC
        8. 7.4.6.8 DEVCTRL CCC
      7. 7.4.7 I/O Operation
      8. 7.4.8 Timing Diagrams
    5. 7.5 Programming
      1. 7.5.1 Enabling Interrupt Mechanism
      2. 7.5.2 Clearing Interrupt
    6. 7.6 Register Map
  8. Application and Implementation
    1. 8.1 Application Information
    2. 8.2 Typical Application
      1. 8.2.1 Design Requirements
      2. 8.2.2 Detailed Design Procedure
      3. 8.2.3 Application Curves
    3. 8.3 Power Supply Recommendations
    4. 8.4 Layout
      1. 8.4.1 Layout Guidelines
      2. 8.4.2 Layout Example
  9. Device and Documentation Support
    1. 9.1 Receiving Notification of Documentation Updates
    2. 9.2 Support Resources
    3. 9.3 Trademarks
    4. 9.4 Electrostatic Discharge Caution
    5. 9.5 Glossary
  10. 10Mechanical, Packaging, and Orderable Information

Package Options

Refer to the PDF data sheet for device specific package drawings

Mechanical Data (Package|Pins)
  • YAH|6
Thermal pad, mechanical data (Package|Pins)
Orderable Information

SETHID CCC

The SETHID CCC is issued by the host controller to the TMP139 to update the HID code of the device serial address. The CCC takes effect after a Stop has been issued by the host controller. Once the SETHID is received, the TMP139 shall update the MR7 register bits DEV_HID_CODE[2:0] to the value HID[2:0] as sent in the CCC data payload when Stop bus condition is sent by the host.

GUID-24E8E773-1E20-47CC-8C6C-285D580BA146-low.gifFigure 7-40 SETHID CCC Broadcast
Note:

TMP139 NACKs the SETHID CCC if the previous transaction has a parity error and the host starts the transaction with a Repeated Start.