SBOS441I September 2009 – October 2019 TMP431 , TMP432
PRODUCTION DATA.
The Conversion Rate Register (pointer address 0Ah) controls the rate at which temperature conversions are performed. This register adjusts the idle time between conversions but not the conversion timing itself, thereby allowing the TMP43x power dissipation to be balanced with the temperature register update rate. Table 9 shows the conversion rate options and corresponding current consumption.
CONVERSION RATE REGISTER (Read = 04h, Write = 0Ah, POR = 07h) | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
R7 | R6 | R5 | R4 | R3 | R2 | R1 | R0 | CONVERSION PER SEC | AVERAGE IQ (TYP) (μA) | |
V+ = 2.7 V | V+ = 5.5 V | |||||||||
0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0.0625 | 11 | 32 |
0 | 0 | 0 | 0 | 0 | 0 | 0 | 1 | 0.125 | 17 | 38 |
0 | 0 | 0 | 0 | 0 | 0 | 1 | 0 | 0.25 | 28 | 49 |
0 | 0 | 0 | 0 | 0 | 0 | 1 | 1 | 0.5 | 47 | 69 |
0 | 0 | 0 | 0 | 0 | 1 | 0 | 0 | 1 | 80 | 103 |
0 | 0 | 0 | 0 | 0 | 1 | 0 | 1 | 2 | 128 | 155 |
0 | 0 | 0 | 0 | 0 | 1 | 1 | 0 | 4 | 190 | 220 |
07h to 0Fh | 8 | 373 | 413 |