Table 9-1 shows the design requirements for TPS2663x.
DESIGN PARAMETER | EXAMPLE VALUE | |
---|---|---|
V(IN) | Typical input voltage | 24 V |
V(UV) | Undervoltage lockout set point | 18 V |
V(OV) | Overvoltage cutoff set point | 33 V |
I(LIM) | Overload current limit | 2 A |
I(INRUSH) | Inrush current limit | 500 mA |
P(OUT) | Output load | 15 W (DC-DC) with 15-V VINminDC-DC |
T(FAIL_TR) | Power interruption time | 10 ms |
P(Surge) | IEC61000-4-5 surge test level | ± 500-V, 2-Ω generator impedance |