over operating free-air temperature range (unless otherwise noted)(1)(2) | MIN | MAX | UNIT |
---|
Input voltage range | VIN, VCC, EN | –0.3 | 20 | V |
VBST | –0.3 | 26 |
VBST (with respect to SW) | –0.3 | 6.5 |
SS, VO, VFB | –0.3 | 6.5 |
SW | DC | –2 | 20 |
Transient < 10 ns | –3 | 20 |
Voltage differential | GND to PowerPAD | –0.2 | 0.2 | V |
Output voltage range | PG, VREG5 | –0.3 | 6.5 | V |
PGND | –0.3 | 0.3 |
Output current | IOUT | | 1.5 | A |
Storage junction temperature | –55 | 150 | °C |
Operating junction temperature | –40 | 150 | °C |
(1) Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only and functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) All voltages are with respect to GND. Currents are positive into and negative out of the specified terminal.