The inductor value has a direct effect on the ripple current. The selected inductor has to be rated for its DC resistance and saturation current. The inductor ripple current (ΔIL) decreases with higher inductance and increases with higher VI or VO.
Equation 6 calculates the maximum inductor current in PWM mode under static load conditions. The saturation current of the inductor must be rated higher than the maximum inductor current as calculated with Equation 7. TI makes this recommendation because during heavy load transient, the inductor current rises above the calculated value.
where
where
A more conservative approach is to select the inductor current rating just for the switch current limit ILIMF of the converter.
The total losses of the coil have a strong impact on the efficiency of the DC/DC conversion and consist of both the losses in the DC resistance R(DC) and the following frequency-dependent components:
INDUCTOR TYPE | INDUCTANCE (μH) | CURRENT (A) | DIMENSIONS (mm) | MANUFACTURER |
---|---|---|---|---|
XEL4020-102ME | 1.0 | 13.25 | 4 × 4 × 2 | Coilcraft |
DFE252012PD-1R0M | 1.0 | 3.8 | 2.5 × 2.0 × 1.2 | Murata |