SLUSFG2A September 2024 – November 2024 TPS6286A06 , TPS6286B10
PRODMIX
To avoid misoperation of the device at low input voltages, undervoltage lockout (UVLO) is implemented when the input voltage is lower than VUVLO. The device stops switching and the output voltage discharge is active. When the input voltage recovers, the device automatically returns to operation with a soft start.
For TPS6286Bxx, the UVLO bit in the STATUS Register is set when the input voltage is less than the UVLO falling threshold. When the input voltage is below 1.8V (typical), all registers are reset.