SLVSEU9D November 2018 – January 2021 TPS63802
PRODUCTION DATA
The output voltage is set by an external resistor divider. The resistor divider must be connected between VOUT, FB, and GND. The feedback voltage is 500 mV nominal. The low-side resistor R2 (between FB and GND) must not exceed 100 kΩ. The high-side resistor (between FB and VOUT) R1 is calculated by Equation 3.
where
VO [V] | R1 [kΩ] | R2 [kΩ] |
---|---|---|
2.5 | 365 | 91 |
3.3 | 511 | 91 |
3.6 | 562 | 91 |
5 | 806 | 91 |