SBVS087M June 2008 – June 2018 TPS735
PRODUCTION DATA.
The device is disabled under the following conditions:
Table 1 lists the conditions that result in different modes of operation.
OPERATING MODE | PARAMETER | |||
---|---|---|---|---|
VIN | VEN | IOUT | TJ | |
Normal mode | VIN> VOUTnom + VDO and VIN> UVLO | VEN> VEN(HI) | IOUT< ILIM | TJ< 125°C |
Dropout mode | UVLO < VIN< VOUTnom + VDO | VEN> VEN(HI) | — | TJ< 165°C |
Disabled mode
(any true condition disables the device) |
VIN< UVLO – Vhys | VEN< VEN(LO) | — | TJ> 165°C |