SLUSCV8A April 2017 – February 2018 UCC20225
PRODUCTION DATA.
INPUT | DISABLE(2) | OUTPUTS | NOTE | |
---|---|---|---|---|
PWM | OUTA | OUTB | ||
L or Left Open | L or Left Open | L | H | Output transitions occur after the dead time expires. See Programmable Dead Time (DT) Pin |
H | L or Left Open | H | L | |
X | H | L | L | - |