JAJSG65B September 2018 – December 2018 ADS1278-SP
PRODUCTION DATA.
In this TDM data output mode, the data position of the channels remain fixed, regardless of whether the channels are powered down. If a channel is powered down, the data are forced to zero but occupy the same position within the data stream. Figure 74 shows the data stream with channel 1 and channel 3 powered down.