JAJSHJ9A June   2019  – January 2021 BQ25125

PRODUCTION DATA  

  1. 特長
  2. アプリケーション
  3. 説明
  4. Revision History
  5. 概要 (続き)
  6. Device Comparison Table
  7. Pin Configuration and Functions
  8. Specifications
    1. 8.1 Absolute Maximum Ratings
    2. 8.2 ESD Ratings
    3. 8.3 Recommended Operating Conditions
    4. 8.4 Thermal Information
    5. 8.5 Electrical Characteristics
    6. 8.6 Timing Requirements
    7. 8.7 Typical Characteristics
  9. Detailed Description
    1. 9.1 Overview
    2. 9.2 Functional Block Diagram
    3. 9.3 Feature Description
      1. 9.3.1  Ship Mode
        1. 9.3.1.1 Ship Mode Entry and Exit
      2. 9.3.2  High Impedance Mode
      3. 9.3.3  Active Battery Only Connected
      4. 9.3.4  Voltage Based Battery Monitor
      5. 9.3.5  Sleep Mode
      6. 9.3.6  Input Voltage Based Dynamic Power Management (VIN(DPM))
      7. 9.3.7  Input Overvoltage Protection and Undervoltage Status Indication
      8. 9.3.8  Battery Charging Process and Charge Profile
      9. 9.3.9  Battery Supplement Mode
      10. 9.3.10 Default Mode
      11. 9.3.11 Termination and Pre-Charge Current Programming by External Components (IPRETERM)
      12. 9.3.12 Input Current Limit Programming by External Components (ILIM)
      13. 9.3.13 Charge Current Programming by External Components (ISET)
      14. 9.3.14 Safety Timer
      15. 9.3.15 External NTC Monitoring (TS)
      16. 9.3.16 Thermal Protection
      17. 9.3.17 Typical Application Power Dissipation
      18. 9.3.18 Status Indicators ( PG and INT)
      19. 9.3.19 Chip Disable ( CD)
      20. 9.3.20 Buck (PWM) Output
      21. 9.3.21 Load Switch / LDO Output and Control
      22. 9.3.22 Manual Reset Timer and Reset Output ( MR and RESET)
    4. 9.4 Device Functional Modes
    5. 9.5 Programming
      1. 9.5.1 Serial Interface Description
      2. 9.5.2 F/S Mode Protocol
    6. 9.6 Register Maps
      1. 9.6.1  Status and Ship Mode Control Register
      2. 9.6.2  Faults and Faults Mask Register
      3. 9.6.3  TS Control and Faults Masks Register
      4. 9.6.4  Fast Charge Control Register
      5. 9.6.5  Termination/Pre-Charge Register
      6. 9.6.6  Battery Voltage Control Register
      7. 9.6.7  SYS VOUT Control Register
      8. 9.6.8  Load Switch and LDO Control Register
      9. 9.6.9  Push-button Control Register
      10. 9.6.10 ILIM and Battery UVLO Control Register
      11. 9.6.11 Voltage Based Battery Monitor Register
      12. 9.6.12 VIN_DPM and Timers Register
  10. 10Application and Implementation
    1. 10.1 Application Information
    2. 10.2 Typical Application
      1. 10.2.1 Design Requirements
      2. 10.2.2 Detailed Design Procedure
        1. 10.2.2.1 Default Settings
        2. 10.2.2.2 Choose the Correct Inductance and Capacitance
        3. 10.2.2.3 Calculations
          1. 10.2.2.3.1 Program the Fast Charge Current (ISET)
          2. 10.2.2.3.2 Program the Input Current Limit (ILIM)
          3. 10.2.2.3.3 Program the Pre-charge/termination Threshold (IPRETERM)
          4. 10.2.2.3.4 TS Resistors (TS)
      3. 10.2.3 Application Performance Curves
        1. 10.2.3.1 Charger Curves
        2. 10.2.3.2 SYS Output Curves
        3. 10.2.3.3 Load Switch and LDO Curves
        4. 10.2.3.4 LS/LDO Output Curves
        5. 10.2.3.5 Timing Waveforms Curves
  11. 11Power Supply Recommendations
  12. 12Layout
    1. 12.1 Layout Guidelines
    2. 12.2 Layout Example
  13. 13Device and Documentation Support
    1. 13.1 Device Support
      1. 13.1.1 Third-Party Products Disclaimer
    2. 13.2 Receiving Notification of Documentation Updates
    3. 13.3 サポート・リソース
    4. 13.4 Trademarks
    5. 13.5 Electrostatic Discharge Caution
    6. 13.6 Glossary
  14. 14Mechanical, Packaging, and Orderable Information

パッケージ・オプション

メカニカル・データ(パッケージ|ピン)
サーマルパッド・メカニカル・データ
発注情報

Faults and Faults Mask Register

Memory location 0x01h, Reset State: xxxx 0000 (BQ25125)

Figure 9-12 Faults and Faults Mask Register
7 (MSB) 6 5 4 3 2 1 0 (LSB)
x x x x 0 0 0 0
R R R R R/W R/W R/W R/W
LEGEND: R/W = Read/Write; R = Read only; -n = value after reset
Table 9-13 Faults and Faults Mask Register
Bit Field Type Reset Description
B7 (MSB) VIN_OV R x 1 - VIN overvoltage fault. VIN_OV continues to show fault after an I2C read as long as OV exists
B6 VIN_UV R x 1 - VIN undervoltage fault. VIN_UV is set when the input falls below V(UVLO) - VUVLO(HYS). VIN_UV fault shows only one time. Once read, VIN_UV clears until another UVLO event occurs.
B5 BAT_UVLO R x 1 – BAT_UVLO fault. BAT_UVLO continues to show fault after an I2C read as long as BAT_UVLO conditions exist.
B4 BAT_OCP R x 1 – BAT_OCP fault. BAT_OCP is cleared after I2C read.
B3 VIN_OV_M R/W 0 1 – Mask VIN overvoltage fault
B2 VIN_UV_M R/W 0 1 – Mask VIN undervoltage fault
B1 BAT_UVLO_M R/W 0 1 – Mask BAT UVLO fault
B0 (LSB) BAT_OCP_M R/W 0 1 – Mask BAT_OCP fault
If a fault is read on the status register and it is neither of any of the faults in this register or subsequent registers, it indicates an ILIM fault.