JAJST23 June   2024 BQ41Z50

ADVANCE INFORMATION  

  1.   1
  2. 特長
  3. アプリケーション
  4. 概要
  5. 概要 (続き)
  6. Pin Configuration and Functions
    1. 5.1 Pin Equivalent Diagrams
  7. Specifications
    1. 6.1  Absolute Maximum Ratings
    2. 6.2  ESD Ratings
    3. 6.3  Recommended Operating Conditions
    4. 6.4  Thermal Information
    5. 6.5  Supply Current
    6. 6.6  Power Supply Control
    7. 6.7  Current Wake Detector
    8. 6.8  VC0, VC1, VC2, VC3, VC4, PACK
    9. 6.9  SMBD, SMBC
    10. 6.10 PRES/SHUTDN, DISP
    11. 6.11 ALERT
    12. 6.12 Coulomb Counter Digital Filter (CC1)
    13. 6.13 ADC Digital Filter
    14. 6.14 CHG, DSG High-side NFET Drivers
    15. 6.15 Precharge (PCHG) FET Drive
    16. 6.16 FUSE Drive
    17. 6.17 Internal Temperature Sensor
    18. 6.18 TS1, TS2, TS3, TS4
    19. 6.19 Flash Memory
    20. 6.20 GPIO1, GPIO2, GPIO3, GPIO4, GPIO5, GPIO6, GPIO7
    21. 6.21 Elliptical Curve Cryptography (ECC)
    22. 6.22 SMBus Interface Timing
    23. 6.23 Typical Characteristics
  8. Detailed Description
    1. 7.1 Overview
    2. 7.2 Functional Block Diagram
    3. 7.3 Feature Description
      1. 7.3.1 Primary (1st Level) Safety Features
      2. 7.3.2 Secondary (2nd Level) Safety Features
      3. 7.3.3 Charge Control Features
      4. 7.3.4 Gas Gauging
      5. 7.3.5 Lifetime Data Logging Features
      6. 7.3.6 Authentication
      7. 7.3.7 Configuration
        1. 7.3.7.1 Oscillator Function
        2. 7.3.7.2 Real Time Clock
        3. 7.3.7.3 System Present Operation
        4. 7.3.7.4 Emergency Shutdown
        5. 7.3.7.5 2-Series, 3-Series, or 4-Series Cell Configuration
        6. 7.3.7.6 Cell Balancing
        7. 7.3.7.7 LED Display
      8. 7.3.8 Battery Parameter Measurements
        1. 7.3.8.1 Charge and Discharge Counting
        2. 7.3.8.2 Voltage
        3. 7.3.8.3 Current
        4. 7.3.8.4 Temperature
        5. 7.3.8.5 Communications
          1. 7.3.8.5.1 SMBus On and Off State
    4. 7.4 Device Functional Modes
  9. Applications and Implementation
    1. 8.1 Application Information
    2. 8.2 Typical Applications
      1. 8.2.1 Design Requirements
      2. 8.2.2 Detailed Design Procedure
        1. 8.2.2.1 High-Current Path
          1. 8.2.2.1.1 Protection FETs
          2. 8.2.2.1.2 Chemical Fuse
          3. 8.2.2.1.3 Lithium-Ion Cell Connections
          4. 8.2.2.1.4 Sense Resistor
          5. 8.2.2.1.5 ESD Mitigation
        2. 8.2.2.2 Gas Gauge Circuit
          1. 8.2.2.2.1 Coulomb-Counting Interface
          2. 8.2.2.2.2 Low-dropout Regulators (LDOs)
            1. 8.2.2.2.2.1 REG18
            2. 8.2.2.2.2.2 REG135
          3. 8.2.2.2.3 System Present
          4. 8.2.2.2.4 SMBus Communication
          5. 8.2.2.2.5 FUSE Circuitry
        3. 8.2.2.3 Secondary-Current Protection
          1. 8.2.2.3.1 Cell and Battery Inputs
          2. 8.2.2.3.2 External Cell Balancing
          3. 8.2.2.3.3 PACK and FET Control
          4. 8.2.2.3.4 Temperature Measurement
          5. 8.2.2.3.5 LEDs
    3. 8.3 Power Supply Recommendations
    4. 8.4 Layout
      1. 8.4.1 Layout Guidelines
        1. 8.4.1.1 Protector FET Bypass and Pack Terminal Bypass Capacitors
        2. 8.4.1.2 ESD Spark Gap
      2. 8.4.2 Layout Example
  10. Device and Documentation Support
    1. 9.1 サード・パーティ製品に関する免責事項
    2. 9.2 Documentation Support
      1. 9.2.1 Related Documentation
    3. 9.3 Receiving Notification of Documentation Updates
    4. 9.4 サポート・リソース
    5. 9.5 Trademarks
    6. 9.6 静電気放電に関する注意事項
    7. 9.7 用語集
  11. 10Revision History
  12. 11Mechanical, Packaging, and Orderable Information

パッケージ・オプション

メカニカル・データ(パッケージ|ピン)
サーマルパッド・メカニカル・データ
発注情報

Device Functional Modes

The BQ41Z50 supports multiple power modes to reduce power consumption:

  • In NORMAL mode, the BQ41Z50 performs measurements, calculations, protection decisions, and data updates in 250ms intervals. Between these intervals, the BQ41Z50 is in a reduced power stage.
  • In SLEEP mode, the BQ41Z50 performs measurements, calculations, protection decisions, and data updates in adjustable time intervals. Between these intervals, the BQ41Z50 is in a reduced power stage. The BQ41Z50 has a wake function that enables exit from SLEEP mode when current flow or failure is detected.
  • In SHUTDOWN mode, the BQ41Z50 is completely disabled.