Over operating free-air temperature range (unless otherwise noted)(1)
| MIN | MAX | UNIT |
---|
Supply voltage range(2) | VDD–VSS | –0.3 | 30 | V |
Input voltage range(2) | V4–V3, V3–V2, V2–V1, V1–VSS, or CD–VSS | –0.3 | 30 | V |
Output voltage range(2) | OUT–VSS | –0.3 | 30 | V |
Continuous total power dissipation, PTOT | See package dissipation rating. | | |
Functional temperature | | –40 | 110 | °C |
Lead temperature (soldering, 10 s), TSOLDER | 300 | | °C |
Storage temperature, Tstg | –65 | 150 | °C |
(1) Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings only, which do not imply functional operation of the device at these or any other conditions beyond those indicated under Recommended Operating Conditions. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) Absolute maximum ratings for input voltage range, output voltage range, and supply voltage are assured by design and not tested in production.